Addendum: Scalers Group 
 
Additional Features of the Scaler Products Group according to 
the Master-Firmware Ver-2.33 Release. 
1. 
This version requires Slave Firmware version 1.06 or higher. The version can be 
seen in the INFO section of the on-screen menu. Contact your Kramer service center if 
you have any questions. 
2. 
Improved functionality lets you select the PIP source via the RS-232 
command. Sending an inappropriate PIP source command (request video PIP source 
while the main video input is selected; or the same for graphic sources) will not cause 
the unit to operate erroneously. In such a case, the unit will ignore the command and 
return the message: “ineffective source”. This option does not apply to the 
VP-719DS
3. 
Added PIP position(s) commands in the RS-232 protocol. These commands 
let you input the absolute value (from 0 to 36) of the horizontal and vertical positions of 
the PIP. For details, see the protocol table. This option does not apply to the 
VP-719DS
4. 
Added new output resolution 1280x768. This resolution is marked with an 
asterisk “*” to attract your attention to the fact that this is not a standard VESA 
resolution and its parameters vary from manufacturer to manufacturer. Therefore, this 
resolution must be used with caution. It is also possible to use the parameters of this 
resolution in combination with the User Defined resolution (see below). There is also an 
RS-232 command for this resolution. For details, see the protocol table. 
5. 
Added 50 Hz output refresh rate. This is for special cases only. Many of the 
modern screens and projectors have difficulties working with such a low frequency. 
6. 
In the OSD under UTILITIES>ADVANCED there is new item: “Input 
Button”. This item defines an action after repeatedly pressing the same input selection 
button. This item has following options: 
FREEZE/BLANK – this is the current situation (quoting from the user 
manual: Press again (when the LED illuminates) to freeze the image; the LED 
flashes. Press once again (when the LED flashes), to display a blank screen; the 
LED flashes more slowly)). This remains the factory default 
FREEZE – pressing the button toggles between LIVE and FREEZE 
BLANK – pressing the button toggles between LIVE and BLANK 
IGNORE – after selecting the source, the button is ignored 
The settings also apply to the input buttons on the IR control. 
7. 
Under the Utility>PIP Setting there is new item: “PIP Frame”. This feature 
allows the enable/disable yellow frame around the PIP through the OSD or the new 
RS-232 command: 
L 50AF. The RS-232 command allows PIP frame enable/disable 
while the PIP is activated. However, before doing it via the OSD you must switch the 
PIP OFF. While the frame is activated, pressing the UP and DOWN buttons on the front 
panel and on the IR remote control would toggle through the PIP size settings. This 
option does not apply to the 
VP-719DS.