GENERAL INFORMATION
Hydraulic system data
Values
Maximum drive system pressure
250 Bar
Maximum accessory system pressure
120/200 Bar
Hydraulic system oil type (at ambient temperature above 10°C)
AGIP Arnica 46 (****)
NOTE
If the machine is to be used at ambient temperatures below 10°C, the oil should be replaced with equivalent oil having a 
viscosity of 32 cSt. For temperatures below 0°C, use oil with lower viscosity.
(****) 
See the below hydraulic system oil technical data and reference data tables.
TECHNICAL DATA
REFERENCE DATA
AGIP ARNICA
46
32
ISO-L-HV
Viscosity at 40°C
mm
2
/s
45
32
ISO 11158
Viscosity at 100°C
mm
2
/s
7.97
6.40
AFNOR NF E 48603 HV
Viscosity index
/
150
157
AISE 127
Flash point COC
°C
215
202
ATOS Tab. P 002-0/I
Pour point
°C
-36
-36
BS 4231 HSE
Density at 15°C
kg/l
0.87
0.865
CETOP RP 91 H HV
COMMERCIAL HYDRAULICS
Danieli Standard 0.000.001 (AGIP ARNICA 
22, 46, 68)
EATON VICKERS I-286-S3
EATON VICKERS M-2950
DIN 51524 t.3 HVLP
LAMB LANDIS-CINCINNATI P68, P69 and 
P70
LINDE
PARKER HANNIFIN (DENISON) HF-0
REXROTH RE 90220-1/11.02
SAUER-DANFOSS 520L0463
ENVIRONMENTAL CONDITIONS
In the environment where the machine operates, there must not be any danger of explosion.
To avoid inhaling exhaust gas, the machine must be used only where there is a proper air change.
The machine operates correctly (*) in the following environmental conditions:
Temperature: -10°C to +40°C
Humidity: 30% to 95%, not condensed
Store the machine indoor, in a clean and dry place, protected from bad weather conditions and with the following values:
Temperature: +1°C to +50°C
Humidity: maximum 95%, not condensed
(*)  When using the sweeper at a temperature between -10°C and 0°C the dust control system cannot be used; moreover the 
water tanks and the dust control system itself must be empty.