Nilfisk Alto ATTIX 965-2H/M SD XC User Manual

Page of 30
16
1) 
Optional accessories / Option depending on model
Original Instructions
ATTIX 9 H/M
4.2.4 Auto-On/Off-Operation 
- "auto" switch 
position 
1)
The vacuum cleaner is switched on 
and off by the power tool connect-
ed. Dirt is picked up from the source 
of dust immediately.
To comply with regulations, only ap-
proved dust producing tools should 
be connected.
The maximum power consumption 
of the connected electrical appli-
ance is stated in section 9.5 "Tech-
nical data".
Before switching the switch to posi-
tion „auto“, ensure that the tool con-
nected to the appliance socket is 
switched off.
1.  Switch off the vacuum clean-
er.
2. Switch off the power tool.
auto
ø
ø
0
ø
ø
3
3
6
5
2
2
7
3.  Connect the power tool and 
the vacuum cleaner with a 
suction hose.
4.  Insert the plug of the pow-
er tool into the tool socket 
on the operating panel 
of the vacuum cleaner.
5.  Switch on the vacuum clean-
er. Switch in "auto" position.
6.  Switch on the power tool. The 
vacuum cleaner motor starts 
when the connected power 
tool is switched on.
When the power tool is 
switched off, the vacuum 
cleaner continues to run for 
a short moment so that any 
dust in the suction hose is 
conveyed to the filter bag.