Fault
Cause
Remedy
‡ Motor does not start
> Fuse of the mains socket has 
blown.
Connect mains fuse.
> Overload protection switch 
has tripped.
Switch off the vacuum cleaner 
and allow it to cool for approx. 
5 minutes. If the cleaner 
cannot be started again, 
contact the Nilfisk-Alto service 
department.
> Motor is faulty.
Have motor changed by 
Nilfisk-Alto Service.
‡ Motor does not run in 
automatic mode 
1)
> Power tool/pneumatic tool is 
defective or not connected 
properly.
Check that the power tool 
works or that the plug is 
inserted correctly.
> The power rating of the 
electrical tool is too low.
Note that minimum power 
rating is P>40W
‡ The acoustic warning 
sounds. (Reduced suction 
power)
> Suction power selected with 
suction power control is too 
low.
Set suction power in 
accordance with section 
„Setting suction power“.
> Hose diameter does not cor-
respond with switch position.
Set correct switch position for 
hose diameter.
> Clogged suction hose/nozzle.
Clean suction hose/nozzle
> The safety filter bag is full.
See section „Replacing the fil-
ter bag“.
> Filter element is clogged.
See section „Cleaning filter 
element“ and „Replacing filter 
element“.
> Cleaning mechanism is 
defective.
Contact Nilfisk-Alto Service.
‡ No suction power during 
wet cleaning 
> Tank is full. 
Switch off the cleaner. Empty 
the tank.
‡ Voltage fluctuations
> Impedance of power supply is 
too high.
Connect the cleaner to another 
socket closer to the fuse box. 
Voltage fluctuations over 
7% should not occur if the 
impedance at the transfer point 
is 
0.15 .