Nilfisk Alto 30 H User Manual

Page of 32
3
english
ATTIX 30/50 H/M
Dust Class M (medium). The dusts which belong to this class 
are: dusts with OEL values
1)
 > 0.1 mg/m³ as well as saw dust. 
The machine is tested in its entirety by vacuums for this dust 
class. The  maximum  degree  of  permeability  is  0.1%  and  the  dis-
posal must be low dust.
The air flow in Safety Vacuum systems has to be strictly controlled 
to achieve a minimum flow rate of V
min
 = 20 m/s in the suction hose.
The vacuum cleaners ATTIX 30-XH and ATTIX 50-XH are suitable 
to pick up
• 
dry, nonflammable dust, non flammable liquids, hazadous dusts 
with OEL values, carcinogenic dusts, dusts containing germs
The vacuum cleaners ATTIX 30-XH PC e ATTIX 50-XH PC are also 
approved for asbestos abatement (TRGS 519).
The vacuum cleaners ATTIX 30-XM and ATTIX 50-XM are suitable 
to pick up
• 
dry,  nonflammable  dust,  non  flammable  liquids,  sawdust  and 
hazadous dusts with OEL values > 0.1 mg/m³
The vacuum cleaners are suitable for commercial use, such as e.g. 
in 
• 
Hotels, Schools, Hospitals, Factories, Shops, Offices, Hire shops
Any other use is considered as improper use. The manufacturer ac-
cepts no liability for any damage resulting for such use. The risk for 
such use is borne solely by the user.
Proper use also includes proper operation, servicing and repairs as 
specified by the manufacturer.
Transport
1.  Before transporting the dirt tank, close all the locks.
2.  Do not tilt the cleaner if there is liquid in the dirt tank.
3.  Do not use a crane hook to lift the cleaner.
Storage
1.  Store the appliance in a dry place, protected from frost.
Maintenance, cleaning and
repair
During  the  following  work,  ensure  that  dust  is  not  unnecessarily 
spread around. Wear a P2 bresthing mask. 
CAUTION: In the case of asbestos abatement wear additional sin-
gle-use clothing.
Electrical connection
1.  It is recommended that the vacuum cleaner should be connected 
via a residual current circuit breaker.
2.  Arrange the electrical parts (sockets, plugs and couplings) and 
lay down the extension lead so that the protection class is main-
tained.
3.  Connectors and couplings of power supply cords and extension 
leads must be watertight.
Extension lead
1.  As an extension lead, only use the version specified by the man-
ufacturer or one of a higher quality. See operating instructions.
2.  When  using  an  extension  lead,  check  the  minimum  cross-sec-
tions of the cable:
Cable length
Cross section
< 16 A
< 25 A
up to 20 m
1.5 mm
2
2.5 mm
2
20 to 50 m
2.5 mm
2
4.0 mm
2