Nilfisk Alto 12 GALLON RDF User Manual

Page of 14
ATTIX 550-01/550-11 MOBIL/550-21/590-21
ATTIX 12 GALLON / ATTIX 12 GALLON RDF
ATTIX EC 12 GALLON AS/E
22
1) 
Option depending on model
Check it for damage and 
replace if necessary.
5.  Check antistatic clamp (5) 
for damage and have it 
replaced by Alto Service if 
necessary.
6. Check the fl oater (6) for 
proper operation:  When 
you turn the fi lter holder, the 
fl oater should move back 
and forth easily.
7.  Fit a new fi lter element.
8. Fit the fi lter holder and turn it 
clockwise to secure it.
9.  Dispose of the used fi lter 
element in accordance with 
legal regulations.
CAUTION!
Never use the vacuum clean-
er without a fi lter.
6
4
5
8 Troubleshooting
Fault
‡   
Motor does not start
>  Fuse in mains plug has 
blown.
>  Overload protection switch 
has tripped.
>  Self-acting carbon brush is 
worn 
1)
•  Reset the fuse.
•  Switch off the vacuum clea-
ner and allow it to cool for 
approx. 5 minutes. If it can 
not be started again, contact 
the Alto service department.
•  Have carbon brushes 
changed by Alto Service.
‡  Motor does not run in auto-
Cause
Remedy
matic mode
1)
>  Power tool is defective or 
not connected properly.
>  The power rating of the elec-
trical tool is too low.
•  Check that the power tool 
works or that the plug is 
inserted correctly.
•  Note that minimum power 
rating is P>40W