Clean the water level limiting device regularly and check for signs of 
damage.
Only carry out maintenance work described in the operating instruc-
tions.
Always pull the out the mains plug before cleaning and maintenance 
of the vacuum cleaner.
During  maintenance  and  cleaning,  handle  the  vacuum  cleaner  in 
such a manner that there is no danger for maintenance staff or other 
persons.
In the maintenance area
1.  Use filtered compulsory ventilation
2.  Wear protective clothing
3.  Clean the maintenance area so that no harmful substances get 
into the surroundings.
Before  removing  the  vacuum  cleaner  from  the  area  contaminated 
with harmful substances:
1.  Clean the outside of the vacuum cleaner, wipe it clean or pack 
the vacuum cleaner in well sealed packaging
2.  and avoid spreading deposited harmful dust.
After  use,  in  asbestos  contaminated  areas,  the  machine  must  be 
cleaned by an authorised person according to TGRS 519.
During  maintenance  and  repair  work  all  contaminated  parts  that 
could not be cleaned satisfactorily must be:
1.  packed in well sealed bags
2.  disposed of in a manner that complies with valid regulations for 
such waste removal.
At least once a year, a Nilfisk-ALTO technician or an instructed per-
son  must  perform  a  technical  inspection  including  filters,  air  tight-
ness and control mechanisms. According to AA.22.201.2 appliances 
in class H must have their filtration efficiency checked once a year. If 
the effiency of the filter does not fulfil the requirements for dust class 
H, the filter must be replaced, and the new filter must be tested ac-
cording to AA.22.201.2.