Kramer Electronics tp-145 User Manual
KRAMER: SIMPLE CREATIVE TECHNOLOGY
Acquiring the EDID
10
Table 5: TP Connector Pinout
3 6
78
1 2
5
4
1
4 5 7 8
6
3
2
Figure 6: TP Connector
EIA /TIA 568A
EIA /TIA 568B
PIN
Wire Color
PIN
Wire Color
1
Green/White
1
Orange/White
2
Green
2
Orange
3
Orange/White
3
Green/White
4
Blue
4
Blue
5
Blue/White
5
Blue/White
6
Orange
6
Green
7
Brown/White
7
Brown/White
8
Brown
8
Brown
Pair 1 4 and 5
Pair 1
4 and 5
Pair 2 3 and 6
Pair 2
1 and 2
Pair 3 1 and 2
Pair 3
3 and 6
Pair 4 7 and 8
Pair 4
7 and 8
6
Acquiring the EDID
The TP-145 transmitter can capture the EDID information from a display device.
To load the default EDID:
1. Plug the 12V DC power adapter into the power socket on the TP-145 and
1. Plug the 12V DC power adapter into the power socket on the TP-145 and
connect the adapter to the mains electricity.
2. With no display device connected to the TP-145, press the EDID CAPTURE button.
3. The EDID STATUS LED flashes rapidly several times and the new EDID is copied.
3. The EDID STATUS LED flashes rapidly several times and the new EDID is copied.
To capture the EDID information from a display device:
1. Using a short cable
1. Using a short cable
2. Connect power to the display and switch it on.
, connect the XGA INPUT 15-pin HD connector on the
TP-145 to the input XGA connector of the display.
3. Plug the 12V DC power adapter into the power socket on the TP-145 and to
the mains electricity.
4. Press the EDID CAPTURE button.
5. The EDID STATUS LED flashes slowly several times and the EDID is captured.
6. Disconnect the display.
5. The EDID STATUS LED flashes slowly several times and the EDID is captured.
6. Disconnect the display.
1 For example, Kramer model number C-MGM/MGM-1