Kramer Electronics tp-145 User Manual

Page of 15
KRAMER:  SIMPLE CREATIVE TECHNOLOGY 
Acquiring the EDID 
  
 
 
 
10 
Table 5: TP Connector Pinout 
3 6
78
1 2
5
4
1
4 5 7 8
6
3
2
 
Figure 6: TP Connector 
EIA /TIA 568A 
 
EIA /TIA 568B 
PIN 
Wire Color 
PIN 
Wire Color 
Green/White 
Orange/White 
Green 
Orange 
Orange/White 
Green/White 
Blue 
Blue 
Blue/White 
Blue/White 
Orange 
Green 
Brown/White 
Brown/White 
Brown 
Brown 
 
 
Pair 1  4 and 5 
Pair 1 
4 and 5 
Pair 2   3 and 6 
Pair 2 
1 and 2 
Pair 3  1 and 2 
Pair 3 
3 and 6 
Pair 4  7 and 8 
Pair 4 
7 and 8 
Acquiring the EDID 
The TP-145 transmitter can capture the EDID information from a display device. 
To load the default EDID: 
1.  Plug the 12V DC power adapter into the power socket on the TP-145 and 
connect the adapter to the mains electricity.  
2.  With no display device connected to the TP-145, press the EDID CAPTURE button. 
3.  The EDID STATUS LED flashes rapidly several times and the new EDID is copied. 
To capture the EDID information from a display device: 
1.  Using a short cable
2.  Connect power to the display and switch it on. 
, connect the XGA INPUT 15-pin HD connector on the 
TP-145 to the input XGA connector of the display. 
3.  Plug the 12V DC power adapter into the power socket on the TP-145 and to 
the mains electricity. 
4.  Press the EDID CAPTURE button. 
5.  The EDID STATUS LED flashes slowly several times and the EDID is captured. 
6.  Disconnect the display. 
 
 
 
 
                                                        
1 For example, Kramer model number C-MGM/MGM-1