Connecting the TP-145 and the TP-146 
 
4.2.1  Internal Polarity and Sync Mode Switches 
 and 
 define the internal horizontal and vertical polarity switches of 
the TP-146
Note: You need to open the TP-146 unit to gain access to the Hs and Vs polarity 
and video selection switches which are located on the lower part of the printed 
circuit board next to the ON LED. After setting the switches, close the TP-146
 
Figure 3: TP-146 Internal Polarity Switches 
Table 3: TP-146 Internal Polarity Switches and Descriptions 
Switch/Jumper 
Function 
SW1 Horizontal Sync Switch 
Slide up to set the H Sync to positive polarity  
Slide down to set the H Sync to negative polarity  
Default = up (positive polarity) 
SW2 Vertical Sync Switch 
Slide up to set the V Sync to positive polarity  
Slide down to set the V Sync to negative polarity  
Default = up (positive polarity) 
SW3 Video Selection Switch 
Slide left to set the video to RGBHV/VGA 
Slide right to set the video to Component/Composite video with sync 
Default = left (RGBHV/VGA video) 
Connecting the TP-145 and the TP-146 
You can use the TP-145 UXGA/Audio/Data Line Transmitter and the TP-146 
UXGA/Audio/Data Line Receiver to configure a TP transmitter and receiver system 
that transmit video, audio, and RS-232 control signals via TP cable.