23. Turn on the gas supply to the unit and test the gas 
supply line and union connections by brushing on 
an approved noncorrosive leak detection solution 
(Figure 116).
24. Turn on the electrical and the gas supplies to the 
water heater. Plug in the electric connection from 
the transformer to the electric outlet (Figure 113).
25. Restart the water heater by following the 
directions on the “Lighting and Operating 
Instructions” label located on the front of the water 
heater .
26. As the burner is heating (view flames through 
viewport), test the manifold tube connection at 
the gas control valve/thermostat by brushing on 
an approved noncorrosive leak detection solution 
(IMPORTANT: Do Not splash any solution onto 
any electrical connections) (Figure 120).
27. Upon verifying proper operation of the water 
heater, replace the manifold cover/outer door.
 
IMPORTANT:
WHEN BRUSHING ON AN 
APPROVED NONCORROSIVE
LEAK DETECTION SOLUTION,
DO NOT SPLASH SOLUTION 
ONTO ELECTRICAL CON-
NECTIONS.
IGNITER/
FLAME
SENSE
CONNECTOR
MANIFOLD TUBE
POWER SUPPLY
TRANSFORMER
CONNECTOR
PRESSURE
SWITCH/FAN,
FV SENSOR
CONNECTOR
DISPLAY, ANODE
ROD CONNECTOR
GAS CONTROL
VALVE/THERMOSTAT
Figure 120.
Checking the Gas Supply Pressure
Gas  pressure  checks  are  done  with  flowing  gas                  
using a gas pressure gauge capable of reading 
pressure in inches of water column. 
GAS 
PRESSURE
GAUGE
CONNECTED AT
PRESSURE TAP
GAS CONTROL 
VALVE/
THERMOSTAT 
SUPPLY GAS PRESSURE TEST
USE AN ALLEN
WRENCH TO REMOVE
AND REPLACE PLUG.
GAS CONTROL 
VALVE/
THERMOSTAT 
MANIFOLD GAS PRESSURE TEST
IF . . .
. . . THEN
supply gas pressure is under desired pressure 
requirement
• 
increase supply gas pressure regulator setting 
and,
• 
increase supply gas piping size.
supply gas pressure is over desired pressure
• 
add gas pressure regulator.
• 
reduce setting on existing regulator.
manifold gas pressure is more than +/- .3 inch 
W.C. from values indicated on gas valve
• 
ensure there is adequate supply gas pressure
• 
ensure the main burner orifi ce is the correct size 
for the water heater model being tested.
• 
if the above tests have been performed and the 
results were correct replace the gas control valve.
Figure 121
Supply gas pressure checks are measured 
before the gas control valve/thermostat and 
as close to the water heater as possible.
Manifold (main burner) gas pressure is 
measured at the pressure tap on the side 
of the gas control valve/thermostat. Use 
an allen wrench to remove the plug then 
attach the gas gauge.
NOTE: Desired gas pressures will be noted on 
the gas valve label located on the gas control 
valve/thermostat.
CHECKING THE GAS SUPPLY PRESSURE