5b: Important Note Regarding PTR Valve
 
The Pressure & Temperature relief valve should be checked for adequate performance or replaced 
at intervals not exceeding 5 years, or less in areas where there is a high incidence of water 
deposits. Providing there is some discharge from the relief valve during each heating cycle there is 
no requirement to manually activate the release mechanism on the relief valve. There is a 
possibility that manually opening the relief valve may allow contamination / grit etc to settle in the 
valve seat causing continuous leakage. If the relief valve is operated manually it should be done 
with care. 
The Pressure & Temperature relief valve and the drain outlet pipe must not be sealed or blocked. It 
is normal for small amounts of water to leak from the valve during each heating cycle. 
 
Section 6: MAINTAINANCE & SERVICE INFORMATION 
 
Your Quantum water heater is a completely sealed refrigeration system, similar to a household 
refrigerator. The maintenance program to be employed on your Quantum is not much different to 
that required for the maintenance of a standard electric water heater. However, Quantum warranty 
may be void if any of the following conditions are not met 
or if the refrigeration lines or 
components are damaged or altered in any unauthorized way. 
6a: The Water Tank 
The water tank must not be drilled or punctured. Drilled holes or punctures may damage the 
refrigeration pipes located on the skin of the water tank. The Quantum tank is a patented design 
and in fact forms the condenser of the unit; i.e. it is the hot side of the refrigeration circuit. The 
coils wound around the outside wall of the tank heat the tank more efficiently than any other water 
heater design. The coils are not in contact with the water so they never corrode or suffer from 
scaling, meaning the efficiency of the tank will not diminish. 
6b: Air Evaporator Coils 
Quantum water heaters use evaporator coils to extract heat from the air. The coil is extremely 
efficient in warm humid weather; however, as temperatures drop to ten degrees or less the coil will 
begin to collect ice. The coil has been designed with "heat injection" to defrost the coil under such 
conditions. The heat injection cycle is automatic and is managed by the digital controller. It is 
important that the air inlet vents are kept clean. Restriction of air-inlet or outlet vents may 
void warranty if the system has been damaged because of insufficient airflow
6c: Sacrificial Anode 
A sacrificial anode is fitted inside the vitreous enamel lined cylinder. Its purpose is to help protect 
the cylinder from the corrosive effects of water. Normally, the sacrificial anode should be 
inspected every fifth year and replaced if necessary. In areas where “hard water” or poor quality 
water conditions exist, the sacrificial anode must be inspected every second year. Replacement 
anodes must meet Quantum quality specifications and must be appropriate for local water 
conditions. 
The anode socket in the top of the tank is an RP 
3
/
/ 20 thread, an 1
1
/
16
” socket wrench 
is required to unscrew it. 
 