Quantum 340-17ACW-134 User Manual

Page of 40
Owner’s Manual
                                                        Quantum  Energy  Technologies 
 
2c: Features Of Your Quantum Water Heater 
 
1.  Fully welded steel tank with class X vitreous enamel lining for superior corrosion 
resistance and longer life. 
2.    Indirect heat transfer eliminates tank hot spots. 
3.    One of the most energy efficient Heat Pump systems in the world. 
4.    Able to save more money, especially in cold weather, than any other solar system on the 
market. 
                                    Warranty Return Card 
Enclosed you will find a warranty card – please fill in the details and return immediately. This will 
ensure prompt service under warranty, if required (see Section 8 for terms of warranty). 
 
Section 3: INSTALLATION DETAILS 
3a: General Installation Requirements 
This water heater must be installed by a licensed tradesperson, and in accordance with 
1.    AS 3500.4, National Plumbing And Drainage Code, Part 4: Hot Water Supply Systems. 
2.    AS 3500.4.2, National Plumbing And Drainage Code, Part 4.2: Hot Water Supply Systems 
– Acceptable Solutions. 
3.    Other relevant Australian Standard, Industry or Local Water Supply regulations or codes 
for mains pressure storage tanks. 
Note: This water heater is not suitable for pool heating or building heating. 
3a.1: Location 
The water heater should be located as close as possible to the most frequently used hot water 
outlets. Adequate access must be made for service to the evaporator, water temperature thermostat, 
relief valve and anode. Ensure that the specification label is clearly visible. The front service cover 
of the heat pump section (on top of tank) must be accessible from the front of the heater; this must 
NOT face the wall. The fan MUST NOT be up against a wall (minimum clearance 500mm). 
The Compact model has a noise level similar to an air conditioner (52dBA @ 1.5 metre); therefore 
locating the unit away from bedrooms or living areas is recommended (both the owners & any 
neighbours). Obviously installing near a bedroom window may be annoying to the occupants. 
Note:      All models are equipped with a sacrificial anode, accessible through the top cover. We 
recommend allowing 400mm above the top of the water heater (if possible) for clearance to 
replace the anode.
 
The water heater should be placed on a 650mm x 650mm plinth if installed on a floor subject to 
wet conditions or outdoors. A properly drained overflow tray should be used where property 
damage could occur from water spillage. (See AS3500.4 for further details.) 
Note:      The warranty does not cover damage due to leakage of the water heater
                                                       
Document number: QDC0030PD-11                                                                                                  Page 7 of 40