State Industries GS675YRVLT User Manual

Page of 36
9
facts to consIder aBout the locatIon
Carefully choose an indoor location for the new water heater, because 
the placement is a very important consideration for the safety of the 
occupants in the building and for the most economical use of the 
appliance. 
this  water  heater  is  not  for  use  in  manufactured 
(mobile) homes or outdoor installation.
Whether replacing an old water heater or putting the water heater in 
a new location, the following critical points must be observed:
1.  Select a location indoors as close as practical to the vent terminal or 
location to which the water heater vent piping is going to be connected, 
and as centralized with the water piping system as possible.  
2.  Selected location must provide adequate clearances for servicing 
and proper operation of the water heater.
Installation of the water heater must be accomplished in such a manner 
that if the tank or any connections should leak, the flow will not cause 
damage to the structure. For this reason, it is not advisable to install 
the water heater in an attic or upper floor. When such locations cannot 
be avoided, a suitable metal drain pan should be installed under the 
water heater. Drain pans are available at your local hardware store.  
Such a drain pan must have a clearance of at least 1.0” (2.5cm) 
greater than any point on the water heater’s outer jacket and must 
be piped to an adequate drain. The pan must not restrict combustion 
air flow. For example, if a circular pan is used, it must be a minimum 
of 27” (69cm) in diameter, see Figure 1.
Water heater life depends upon water quality, water pressure and  
the environment in which the water heater is installed. Water heaters are 
sometimes installed in locations where leakage may result in property 
damage, even with the use of a drain pan piped to a drain. However, 
unanticipated damage can be reduced or prevented by a leak detector or 
water shut-off device used in conjunction with a piped drain pan. These 
devices are available from some plumbing supply wholesalers and 
retailers, and detect and react to leakage in various ways:
•  Sensors mounted in the drain pan that trigger an alarm or turn off the 
incoming water to the water heater when leakage is detected.
•  Sensors mounted in the drain pan that turn off the water supply to 
the entire home when water is detected in the drain pan.
•  Water supply shut-off devices that activate based on the water 
pressure differential between the cold water and hot water pipes 
connected to the water heater.
•  Devices that will turn off the gas supply to a gas water heater while 
at the same time shutting off its water supply.
INSTALLATIONS  IN AREAS  WHERE  FLAMMABLE  LIQUIDS 
(VAPORS)  ARE  LIKELY  TO  BE  PRESENT  OR  STORED 
(GARAGES, STORAGE AND UTILITY AREAS, ETC.): Flammable 
liquids (such as gasoline, solvents, propane (LP or butane, etc.) and 
other substances (such as adhesives, etc.) emit flammable vapors 
which can be ignited by a gas water heater’s hot surface igniter or 
main burner. The resulting flashback and fire can cause death or 
serious burns to anyone in the area.
Also, the water heater must be located and/or protected so it is not 
subject to physical damage by a moving vehicle.
locatInG the new water heater
This water heater must not be installed directly on carpeting. Carpeting 
must be protected by metal or wood panel beneath appliance extending 
beyond full width and depth of appliance by at least 3” (7.6 cm) in any direction, 
or if appliance is installed in an alcove or closet, entire floor must be covered 
by the panel. Failure to heed this warning may result in a fire hazard.