Haier ES10V-M2 Leaflet

Page of 2
60
Do not confuse the water inlet and outlet pipes. The wall bearing the water heater shall be strong 
5
6
3
4
b
d
e
c
a
Front 
view
Side 
view
Cutaway 
view
Rear 
view
(Figure 1)
The safety valve should be connected to the water inlet pipe. Please check carefully if the 
direction is correct after installation. The correct direction of installation is that the arrowhead 
on the safety valve should point to the water heater.
Please connect the drain hose to the safety valve. Connect one end of the hose to the safety 
valve vent and the other end to the sewage drain for fear of indoor contamination. The hose 
can be cut short or extended as necessary. The hose shall be installed as inclined downward.
The heater should work with the safety valve whose rated pressure is 0.80MPa.
During heating, water may drip from the drain hose of the pressure relief hole due to 
expansion and the hole must be left open to the atmosphere. Check safety valve once a 
The pressure relief hole is to be operated regularly to remove lime deposits and to verify that it is not blocked.
enough to endure a weight twice as much as that of a water heater f
 
illed with water. Do not secure it 
by means of adhesive or similar products because the f
 
ixation by such methods is unreliable.
(Figure 3) for installation 
reference only
(Figure 2)
Extended connection line
Wall rack
Expansion
hook
Cold water  inlet
Mixing
valve
Hot water
outlet valve
Cold water
outlet valve
Shower  head
Hot water outlet
Safety valve
Connection and use of safety valve
Attention during installation
Safety precautions
Please fasten the drain hose to the pressure relief hole of the safety valve by twisting (see to 
Figure 4). Connect the other end of drain hose to the sewer to avoid polluting the room by 
splashing. When the power is switched on, and the water heater starts operating, there may 
be some water discharged from the pressure relief hole of the safety valve. It is due to the 
water expansion under heating, and is a normal phenomenon. The pressure relief pipe shall 
communicate with the air directly. Do not block it. The drain hose connecting to the safety 
valve shall be kept downward sloping in installation and in a frost-free environment.
Be sure to check and conf
 
irm that the tank is f
 
illed with 
water, there is no leakage at each joint and the power supply 
complies with the stipulation before switching on the power.
This heater must be equipped with the safety valve along 
with the machine; otherwise any safety accident and property 
loss caused thereby shall be the user's own responsibility.
To avoid danger caused by accidental resetting of the heating breaker, the power for the heat 
cannot be supplied by timer and other external switch devices or connected to circuit with 
frequent switching for facility use.
If any part is damaged, please contact the local maintenance agent and have it replaced with 
our spare parts.
 Tap water inlet pressure shall be no less than 0.05MPa and the maximum pressure shall not 
exceed 0.75MPa.
After installation, as the tank is empty in the f
 
irst usage, be sure to open the tap water inlet 
valve and turn to the top temperature button on the mixing valve. When the tank is f
 
illed 
with water, and the shower nozzle or other water outlet keeps the water output, please close 
the mixing valve, check if there is water leakage at each joint and plug the power.
Turn the knob as per the needed water temperature. The setting temperature rises gradually 
when the temperature regulating knob is rotated clockwise; when setting to the maximum 
temperature, the knob cannot be rotated any more; the temperature decreases gradually in 
case of anticlockwise rotation of the knob. The mark of the knob increases from the actual 
temperature to 75
o
C. You can set the heating temperature steplessly. The heating indicator 
will light on under heating mode. Generally, the knob should be set to the highest scale. The 
automatically when the set temperature is reached, and will be switched on automatically when 
the temperature drops to a certain level. As it continues heating, you can use hot water as well.
When the tap water inlet pressure arrives at or exceeds 0.80MPa, the drain hose of safety 
valve will discharge a large amount of water. It is due to extra high water pressure. Please 
contact the local after service agent for disposal.
In long-term out-of-use or maintenance of the heater, you can close the city water pipe valve 
and set the mixing valve to the highest water temperature rate after opening the safety valve 
handle. Move up the safety valve handle to drain the tank. To avoid injury, before the next 
use, it is suggested to f
 
irst open hot water valve before switching on the water heater, exhaust 
gas possibly retained in the pipeline. In this case, no smoke or f
 
ire is permitted near the open 
valve. Carefully check and conf
 
irm all parts are in good condition.
Usage
Features
Safety: High quality heatproof stainless steel electric heating element, over-temperature 
protection; overpressure protection of tank; safe and reliable. The third-generation "Safe Care" 
design for safer usage.
Durability: Full plastic shell, handsome and durable. Enamel tank, with reliable quality and 
long operation life.
Convenience: Adjustable water temperature; water inlet adjusting range: actual temperature 
~75
o
C.
Multiple usage: Enclosed structure, capable of supplying water to multiple places like toilet, 
kitchen etc. Suitable for family, enterprises, service trades like beauty care on hot water 
supply (not drinkable).
Cleaning and maintenance
FAQ
Disconnect power supply before cleaning. Gently wipe with wet cloth dipped with a little 
mild detergent. Do not use gasoline or other solvents. Finally dry with a dry cloth. Keep 
water heater dry.
 
iciency, heating elements and tank liner of water heater shall be 
cleaned once every three years. Take care not to damage the protection layer on heating 
elements and tank liner surface. According to the local water quality, magnesium rod shall 
be periodically replaced. If maintenance is needed, please contact a local service station.
Phenomenon
Conf
 
irmation items
Remedy
No water
No water supply or water 
pressure too low
Check
Water use point is blocked or hot 
water valve is closed
Check and clear
Only cold water 
but pointer light 
when heat
Hot water access close
Check and open
Temperature not set to desired 
setting
Adjust the temperature of water
Heating time limit and setting 
temperature not obtained
Keep heating
Defective heater
Contact with service department 
when 1, 2 and  3 are excluded.
Only cold water 
and pointer not lit 
when heated
No power to heater
Check power socket
Uncontrollable thermostat
Contact with service department 
when 1 is excluded.
Heating pointer 
always lit
Setting water temperature not 
obtained
Keep heating
Uncontrollable thermostat
Contact with service department 
when 1 is excluded.
and temperature 
of water
 Inconstant water pressure
with constant water pressure
 
icient hot 
water
Temperature set too low
Adjust setting water temperature
Excessive water pressure
Item
Unit
ES10V-M1/M2 ES15V-M1/M2 ES25V-M1/M2
Rated voltage
230
230
230
Rated frequency
Hz
50
50
50
Rated pressure
MPa
0.80
0.80
0.80
Power
W
2000
2000
2000
Net weight
kg
8
10
14
Rated temperature
o
C
75
75
75
Volume
L
10
15
25
Waterproof grade
/
IPX4
IPX4
IPX4
Mixing factor
%
9
11
12
Tap water pressure
MPa No less than 
0.05MPa
No less than 
0.05MPa
No less than 
0.05MPa
Average temperature of hot 
water outlet
o
C
60
60
Re-heating time   
(a temperature rise of 50
o
C) min
18
28
46
Diameter of power wire
mm
2
3×1.5
3×1.5
3×1.5
Nice molding, space-saving: Vertical type wall-mounting design, saving space  
The water heater you purchased is the improved model of the series product. Please operate 
according to the user's manual.
Technical data  Packing list
Parameters
Dimensions
(Figure 4)
Connect 
to drain 
hose
Model
a
b
c
d
e
ES10V-M1/M2
298mm
287mm
501mm
152mm
100mm
ES15V-M1/M2
318mm
300mm
623mm
152mm
100mm
ES25V-M1/M2
378mm
374mm
616mm
152mm
100mm
A Hot water outlet 
B Cold water inlet  C Tank
 
D Heating element
 
E Anode rod
F  Thermometer tube   G Wall-mounting bracket  H Temperature regulating knob
Remarks: 1.  The permitted error limit of the above parameters is ±10%. 
2.  The thermoter is not a precision temperature meter. The dial is divided into three 
zones which are blue, croci and red, only representing the water temperature of 
the heater tank from low to high.  
Remarks: The permitted error limit of net weight above is ±10%.
ES35V-M1/M2
415mm
405mm
663mm
152mm
100mm
ES35V-M1/M2
230
50
0.80
2000
75
35
IPX4
No less than 
0.05MPa
3×1.5
60
65
10
16