Haier ES35V-P2 Leaflet

Page of 2
5
6
3
4
During installation, adequate space must be reserved for future maintenance and repair (at least 300 mm). 
If the water heater is installed within decoration boards, the right board shall be removable to facilitate 
removing the plastic cover during maintenance. 
Tap water inlet pressure shall be no less than 0.05MPa and the maximum pressure shall not exceed 0.75MPa.
Electric water heater shall be installed indoors with ambient temperature above 0°C. The pipes shall be 
collectively laid. Hot water outlet shall not be too far from use points. In case farer than 8 m, hot water pipe 
shall have a thermal insulation to minimize heat loss.
load bearing walls or air brick walls must have corresponding protective measures like additional support, 
wall-through screws or back boards. 
tank or pipes leak, nearby or lower facilities shall not be damaged. The installation location shall avoid being 
above toilet bowl, bathtub, washbasin or doorframe, where will cause a suppressed or unsafe feeling to users.
Do not confuse inlet and outlet water pipes. Safety valve shall be installed at designated position with no 
Use a test pencil to check whether the live line and null line are wrongly connected. Power may only be 
connections. The power supply should also conform to the heater’s requirements.
To avoid danger caused by accidental reset of heating breaker, the power for the heater cannot be supplied by 
timer and other external switch devices or connected to circuit with frequent switching for facility use.
In order to avoid unforeseen accidents, only install components Haier-provided . Do not switch or exchange parts yourself. 
If components are damaged, you must contact the company’s repair center and use the parts supplied by Haier. If to the 
user fails to follow the requirement above, Haier will not be responsible for any direct or indirect damages caused hereof.
Installation warning
Introduction of control panel
Preset Bath Mode
Installation of remote control unit holder
Remote control unit panel
Cleaning and maintenance
Real-time Heating Mode 
C urrent Temp.
H ea ting T emp.
Norma l F a s t T urbo
S P E E D
S E T
T IM E R
kW
O n  
1
2
3
4
5
6
7
8
9
0
A
1  
Actual temperature
2  
Set temperature
3  
Power
4  
Current time
5  
Current time/
temperature increase 
key
6  
Power selection key
7  
Time setting key
8  
Heating Temp. icon Blinking, 
indicates heating is in process; 
temperature is maintained at 
set temperature once it stops 
blinking.
9  
Preset stop-heating)
0  
Preset bath, preset stop-heating 
setting key
A  
is water leakage at the respective joints before connecting power. Once power is connected, the panel will show full 
display for 1 second, accompanied by a buzzer sound. The heater will then enter into shutdown state as before.
Press   key to switch on the heater
Press   key for the heater to interchange between standby state (with clock display only) and working state.
Press 
+
 keys to set the temperature to (35~75°C)
The Heating Temp. value icon on the control panel will blink and changes correspondingly. Once 
the desired value is reached press SET
Press SPEED key repeatedly to select the heating power
This product provides three power settings for your selection. Low (1kW), Medium (2kW), High (3kW).
Press SET key to calibrate the clock.
Press the SET
+
 to set the hour; Press the SET key again, 
+
 to set the minute; After setting, press SET
the value blinks for 6 seconds without any further operation, the system will automatically enter next 
Under real-time heating mode, the heater will automatically heat the water or maintain the 
temperature near the set value. (If the set temperature is lower than 55°C, the heater will heat again 
once the temperature is lower than the set value by 5°C; If the set temperature is between 55°C and 
75°C, the heater will heat again once the temperature is lower than the set value by 10°C.)
This product is equipped with preset bath function. Activate the preset bath function to set the preset 
bath time, power and temperature. If no operation is carried out for 2 minutes after that, the heater will 
enter into power saving mode (display on and current time only). It will also calculate the heating time, 
and heat the water to the preset temperature automatically before the preset time.
Carry out Steps 1~4 of the real-time heating mode
Press the TIMER key, the preset bath icon on displays.
Press SET key to set the preset time
Press the SET
+
 to set the hour; Press the SET key again, 
+
 to set the minute; After setting, press SET
the value blinks for 6 seconds without any further operation, the system will automatically enter next 
Note: If the actual temperature doesn't reach the set temperature at the preset time, the heater will extend 
the heating time by 30 minutes automatically. After 30 minutes the heater will stop heating no mater 
the temperature reaches to the set temperature or not.
 
If by the preset time the actual temperature is that of the set temperature, but the actual temperature 
drops by 5°C by the preset time, the heater will re-heat the water. Once the preset time is reached, it 
will stop heating whether or not the water reaches the set temperature.
Use the correct screws in the accessories to secure the remote control unit 
holder onto a suitable position on the wall; and insert the remote control 
unit into the holder (see illustration below).
 Used to adjust the temperature value
Explanation: The use of the buttons on the remote control unit is the same as that for the 
buttons on the control panel.
Note:  When using the remote control unit it is best to use it at close distance and at a 
perpendicular angle. When the battery in the remote control unit is completely 
exhausted, please remove the cover on its back using a coin to turn the knob in the 
direction as indicated, then remove the button battery inside and replace it with 
prevent explosion. They should be disposed of in accordance with regulations.
Warning
maintenance may cause severe injury or damage.
Disconnect power supply before cleaning. Gently wipe with wet cloth dipped with a little of 
mild detergent. Do not use gasoline or other solvents. Finally dry with dry cloth. Keep water 
heater dry. Do not use cleansers containing grinding agent (e.g. toothpaste), acids, chemical 
elements and tank liner of water heater shall be cleaned once in three years. Take care not 
to damage protection layer on heating elements and tank liner inner surface. According to 
maintenance is needed, please contact local service station.
Friendly reminder: 
1. In long-term out-of-use or maintenance of the heater, you can close the city water pipe 
valve and set the mixing valve to the highest water temperature rate after opening the 
safety valve handle. Move up the safety valve handle to drain the tank.
switching on the water heater, exhausting gas possibly retained in the pipeline. In this case, 
in good condition.
1
2
2
1
4
3
Preset Stop-heating Mode
This product is also equipped with preset stop-heating  mode, i.e. the heater will automatically stop-heating  
at the appointed time.
Carry out Steps 1~4 of the real-time heating mode
Press the TIMER key repeatedly, the preset  stop-heating icon 
 displays
Press the SET key to set the preset  stop-heating time
Press the SET key, how-to is the same as mode 3 of preset bath
Preset bath and preset stop-heating can be set simultaneously. Once the settings are activated, water heater will 
automatically start heating the water to reach the preset temperature before the preset On time based on the current 
time and preset time. In the time between On and Off, water heater is on real-time heating mode (once the water
 temperature drops 5 degree than the preset temperature, heating will be started again). The water heater will automatically 
stop heating when reaches the Off time.
 Note: If the Off time is within the execution time of preset bath, then the Water heater will first stop heating for 1min, then 
continue the heating till ON time.
2
1
3
3
Item
Unit
ES15V-P2
ES25V-P2
ES35V-P2
 Rated voltage
230
230
230
Rated frequency
Hz
50
50
50
Rated pressure
MPa
0.80
0.80
0.80
Power
W
1000/2000/3000
1000/2000/3000
1000/2000/3000
Net weight
kg
10
14
17
Rated temperature
o
C
75
75
75
Volume
L
15
25
35
Technical data ·  Packing list
Parameters
Remarks: 1. The permitted error limit of net weight above is 
±
10%. 
2. The values for mixing factor, average temperature of hot water outlet, re-heating time 
(a temperature rise of 50°C) are all measured under the maximum power condition. 
Front 
view
Side 
view
Cutaway 
view
Rear 
view
b
 a
C
d
e
SPEED
SET
TIMER
Dimensions
Model
a
b
c
d
e
ES15V-P2
316mm
291mm
623mm
152mm
100mm
ES25V-P2
378mm
362mm
616mm
152mm
100mm
ES35V-P2
415mm
398mm
663mm
152mm
100mm
A Hot water outlet 
B Cold water inlet 
C Tank    D Heating element    E Anode rod
 F Thermometer tube   G Wall-mounting bracket 
Remarks: The permitted error limit of above parameters is 
±
10%. 
Packing list
Electric 
water 
heater (Set)
Safety valve 
Drain hose 
(Unit)
Expansion 
hook 
(PCS)
User's 
manual 
(Copy)
Connecting 
line (PCS)
Remote control, 
Remote control 
unit holder (Set)
Accessories 
pack (Unit)
ES15V-P2
1
1
2
1
1
1
1
ES25V-P2
1
1
2
1
1
1
1
ES35V-P2
1
1
2
1
1
1
1
 
Name
Quantity
Model
(Figure 4)
Item
Unit
ES15V-P2
ES25V-P2
ES35V-P2
Waterproof grade
/
IPX4
IPX4
IPX4
Mixing factor
%
13
5
4
Tap water pressure
MPa
No less than 
0.05MPa
No less than 
0.05MPa
No less than 
0.05MPa
Average temperature of hot 
water outlet
o
C
64
68
64
Re-heating time 
(a temperature rise of 50
o
C)
min
14
21
41
Diameter of power wire
mm
2
3×1.5
3×1.5
3×1.5
SPEED
SET