Installation Instructions
ELECTRICAL CONNECTION
INFORMATION
WARNING –
To reduce the risk
of fire, electrical shock and personal injury:
• Do not use an extension cord or an adapter plug
with this appliance.
• The water heater must be electrically grounded
in accordance with local codes and ordinances
or, in the absence of local codes, in accordance
with the NATIONAL ELECTRICAL CODE, ANSI/NFPA
NO. 70, or the CANADIAN ELECTRICAL CODE,
CSA C22.1.
ELECTRICAL REQUIREMENTS
This appliance must be supplied with 120V, 60Hz,
and connected to a properly grounded branch
circuit, protected by a 15- or 20-amp circuit
breaker or time-delay fuse.
If electrical supply provided does not meet the
above specifications, it is recommended that a
licensed electrician install an approved outlet.
WARNING –
This water heater is
equipped with a three-prong (grounding) plug for
your protection against shock hazard and should
be plugged directly into a properly grounded
three-prong receptacle. Do not cut or remove
the grounding terminal from this plug.
ENSURE PROPER GROUND EXISTS BEFORE USE.
DO NOT REMOVE GROUND PRONG.