Kenmore 153 User Manual

Page of 32
8
The upper and lower thermostats are adjustable if a different water 
temperature is desired. Read all warnings in the “Temperature-
Regulation” section before proceeding.
1.  Turn  “OFF”  the  electric  power  to  the  water  heater  at  the 
junction box.
2.  Take off the upper and/or lower access panel, insulation cap 
with handle.
3.  The slotted adjustment (using a screwdriver) can be turned 
clockwise ( 
 ) to increase the temperature setting or counter 
clockwise ( 
 ) to decrease the temperature setting.
4.  Replace the insulation cap with handle and access panel.
5.  Turn “ON” the power supply.
Anode Rod Inspection
The anode rod is used to protect the tank from corrosion. Most 
hot water tanks are equipped with an anode rod. The submerged 
rod sacrifices itself to protect the tank. Instead of corroding the 
tank, water ions attack and eat away the anode rod. This does 
not affect the water’s taste or color. The rod must be maintained 
to keep the tank in operating condition.
Anode  deterioration  depends  on  the  water  conductivity,  not 
necessarily  water  condition. A  corroded  or  pitted  anode  rod 
indicates high water conductivity and should be checked and/or 
replaced more often than an anode rod that appears to be intact. 
Replacement of a depleted anode rod can extend the life of your 
water heater. Inspection should be conducted by calling Sears 
Service Center. At  a minimum the anode(s) should be checked 
annually after the warranty period.
Temperature-Pressure Relief Valve Operation
The temperature-pressure relief valve must be manually operated 
at least once a year.
The temperature-pressure relief valve must be manually operated 
at least once a year. Caution should be taken to ensure that 
(1) no one is in front of or around the outlet of the temperature-
pressure relief valve discharge line, and (2) the water manually 
discharged will not cause any property damage or bodily injury. 
The water may be extremely hot.
FIGURE 28.
If after manually operating the valve, it fails to completely reset 
and continues to release water, immediately close the cold water 
inlet to the water heater, follow the draining instructions, and 
replace the temperature-pressure relief valve with a new one.
Failure to install and maintain a new properly listed temperature-
pressure relief valve will release the manufacturer from any claim 
which might result from excessive temperature or pressure.
If the temperature-pressure relief valve on the appliance weeps 
or discharges periodically, this may be due to thermal expansion. 
your water heater may have a check valve installed in the water 
line  or  a  water  meter  with  a  check  valve.  Consult  your  local 
Sears Service Center for further information. Do not plug the 
temperature-pressure relief valve.
Draining