Wiring CT50/CT53/CT54
•  2-wire heat-only system: Connect one 
wire to R terminal, one wire to W terminal.
M23791
Wiring CT51/CT55
[1] If wires will be connected to both R and Rc
 
terminals, remove the metal jumper.
[2] Do not connect both O and B if you have a 
heat pump. Connect only the O wire. Wrap B 
wire with electrical tape and do not use.
[3] Do not use CX or B. Wrap bare end of wire
with electrical tape.
M23792 
1.  Drill holes at pencil-marked
locations (3/16” holes for  
drywall, 7/32” holes for 
plaster).
2.  Use hammer to tap anchors 
into holes until flush with wall.
3.  Pull wires through thermostat
base and insert screws. 
Check level if desired, then 
tighten screws.
Mount thermostat base
1.  Match each labeled wire with same 
letter on terminal.
2.  Use a screwdriver to loosen screw 
terminals, insert bare wires beneath 
screws, then tighten screws.
3.  Push any excess wire back into the
wall opening.
Labels don't match?
If labels do not match letters on 
thermostat, see table below.
Existing wires  Connect to:
R RH4 V 
Terminal “R
[1]
Rc 
Terminal “Rc”  [1]
O 
Terminal “O”  [2]
B 
Terminal “B”  [2]
GF 
Terminal “G
WW1H 
Terminal “W
Y1M 
Terminal “Y
CB 
Do not use
[3]
CT51/CT55
CT50/CT53/CT54
Connect wires