Honeywell CM921 User Manual

Page of 19
pRoGRAMMING THE CM921 
The Built-in Heating Program
The  built-in  heating  program  has  6  temperature  level  changes  that  can  be  set 
between  3.00am  and  2.50am  -  allowing  you  to  maintain  the  evening  temperature 
after  midnight.  Each  temperature  level  can  be  set  between  5°C  and  35°C,  and 
adjusted in 0.5°C increments. The factory default program for heating is as follows:
Reviewing the Heating Program
To review or edit the heating program move the slider switch to the PROG position 
then  use  the 
  or 
  buttons  to  navigate  between  the  6  individual  programming 
periods.
Modifying the Heating Program
To change the heating program:
a.  Set the slider switch to the PROG position, entering programming mode. ‘SET 
TIME 1’ will be displayed and the time settings for period 
1
 will be lashing. The 
active period is highlighted by a lashing square symbol around the numbers at 
the bottom of the screen.
Period 
6
Time 
6:30 
8:00 
12:00 
14:00 
18:00 
22:30
Temperature 
21°C 
18°C 
21°C 
18°C 
21°C 
16°C
DATE
PROG
AUTO
MAN
OFF
1
6
5
4
3
2