White Rodgers PS9 Up User Manual

Page of 12
269434-UUM-A-0407
USER’S INFORMATION,
MAINTENANCE AND 
SERVICE MANUAL
HIGH EFFICIENCY
TUBULAR HEAT EXCHANGER SERIES
MODELS: PS9*UP / FC9S*UP / FL9S*UP
(Single Stage Upflow)
EFFICIENCY
RATING
CERTIFIED
ISO 9001
Certified Quality
Management System
The manufacturer recommends that the user read all sec-
tions of this manual and keep the manual for future refer-
ence.
 
SECTION I: USER’S INFORMATION
SAFETY
1.
The furnace area must be kept clear and free of combustible mate-
rials, gasoline and other flammable vapors and liquids.
2.
Insulating materials may be combustible. The furnace must be
kept free and clear of insulating materials. The furnace area must
be examined when installed in an attic or other insulated space or
when insulation is added to be sure that the insulation material has
been kept away from the furnace.
3.
The furnace needs air for combustion in order to operate properly
and safely. Do not block or obstruct air openings on the furnace,
air openings to the area where the furnace is installed, or spaces
around the furnace.
4.
Follow the instructions exactly as shown on the OPERATING
INSTRUCTION LABEL or the Start-up and Shutdown Instructions
on Page 3 of this manual when lighting the furnace or turning the
furnace off.
5.
Should the gas supply fail to shut off or if overheating occurs, shut
off the gas valve to the furnace before shutting off the electrical
supply.
6.
Do not use this furnace if any part has been under water. A flood-
damaged furnace is extremely dangerous. Attempts to use the fur-
nace can result in fire or explosion. A qualified service agency
should be contacted to inspect the furnace and replace all gas
controls, control system parts, electrical parts that have been wet
or the furnace if deemed necessary.
FIRE OR EXPLOSION HAZARD - Failure to follow
safety warnings exactly could result in serious injury,
death, or property damage.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
—  WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any 
phone (included cell phone) in your building.
Leave the building immediately.
Immediately call your gas supplier from a neighbor’s 
phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire 
department.
—  Installation and service must be performed by a 
qualified installer, service agency or the gas sup-
plier.
CONTACT INFORMATION
Go to website at www.york.com click on “contact”, then click on “contact form” and follow the instructions.
Contact us by mail:
York International
Consumer Relations
5005 York Drive
Norman, OK 73069
TABLE OF CONTENTS
CONTACT INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
USER’S INFORMATION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
SAFETY   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
INSTRUCTIONS FOR EXAMINING THE 
FURNACE INSTALLATION   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
HOW YOUR GAS FURNACE WORKS   . . . . . . . . . . . . . . . . . . . . . . 3
START-UP AND SHUTDOWN INSTRUCTIONS  . . . . . . . . . . . . . . . 3
Read the Instructions Below Before Trying to Start the Furnace . . 3
Operating Instructions: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
To Turn Off the Appliance: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
FURNACE USER MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Air Filters  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Replacing Filters   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Blower Care  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Motor Lubrication  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
SERVICE AND MAINTENANCE MANUAL  . . . . . . . . . . . . . . . . . . . . .5
SAFETY SECTION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
FURNACE MAINTENANCE SECTION  . . . . . . . . . . . . . . . . . . . . . . .5
SEQUENCE OF OPERATION   . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Continuous Blower  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Intermittent Blower - Cooling   . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Heating Cycle  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Hot Surface Ignition System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
TROUBLESHOOTING   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
FURNACE CONTROL DIAGNOSTICS . . . . . . . . . . . . . . . . . . . . . . .6
DIAGNOSTIC FAULT CODE STORAGE AND RETRIEVAL   . . . . . .7
REPLACEMENT PARTS LIST   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
REPLACEMENT PART CONTACT INFORMATION   . . . . . . . . . . .10
WIRING DIAGRAM   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
LIMITED WARRANTY  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

Summary of Contents of user manual for White Rodgers PS9 Up

  • Page 1USER’S INFORMATION, MAINTENANCE AND EFFICIENCY RATING CERTIFIED SERVICE MANUAL HIGH EFFICIENCY ISO 9001 TUBULAR HEAT EXCHANGER SERIES Certified Quality Management...
  • Page 2269434-UUM-A-0407 INSTRUCTIONS FOR EXAMINING THE FURNACE INSTALLATION BURNER BOX It is the owner’s responsibility to ensure that an annual inspection...
  • Page 3 269434-UUM-A-0407 HOW YOUR GAS FURNACE WORKS To Turn Off the Appliance: Your furnace is a very easy appliance to...
  • Page 4269434-UUM-A-0407 • Check for dirt or lint on any surfaces or on components. Do not try a. If the return...
  • Page 5 269434-UUM-A-0407 3. The furnace burners, ignitor and flame sensor. 4. The condensate collection and disposal system. If any disassem-...
  • Page 6269434-UUM-A-0407 If the flame is not detected within 7 seconds of the gas valve opening, FURNACE CONTROL DIAGNOSTICS the gas...
  • Page 7 269434-UUM-A-0407 9 RED FLASHES: Indicates reversed line voltage polarity or grounding DIAGNOSTIC FAULT CODE STORAGE AND problem. Both heating...
  • Page 8269434-UUM-A-0407 SECTION III: REPLACEMENT PARTS LIST 31 29 26 61 5 10 40 13 51 39 24 69 62 2...
  • Page 9 269434-UUM-A-0407 ITEM DESCRIPTION ITEM DESCRIPTION MOTOR MISCELLANEOUS 1 MOTOR, DIRECT DRIVE BLOWER 37 PLUG, WINDOW, CLEAR -1.5” 2 MOTOR,...
  • Page 10269434-UUM-A-0407 TABLE 2: Field Installed Accessories - Non Electrical MODEL NO. DESCRIPTION USED WITH 1NP0347 PROPANE (LP) CONVERSION KIT ALL...
  • Page 11 269434-UUM-A-0407 SECTION IV: WIRING DIAGRAM FIGURE 8: Wiring Diagram Unitary Products Group 11
  • Page 12 Limited Warranty UPG warrants this product to be free from defects in factory workmanship and material under normal use...