Bosch W11P User Manual

Page of 8
4
6 720 607 526
1.6
Technical characteristics
*
H
i
 15°C - 1013 mbar - dry :
Natural gas
34.2 MJ/m
3
 (9.5 kWh/m
3
)
LPG: Butane 45.7 MJ/kg (12.7 kWh/kg)
Propane 46.4 MJ/kg (12.9 kWh/kg)
**
This figure must not be exceeded taking account of water expansion
***
At maximum rated heat output
Technical Data
Symbol
Unit
W11
W14
W18
Rated max. heat output
P
n
Btu/h
65570
80595
104165
Rated min. heat output
P
min
Btu/h
31420
40300
52082
Output (modulation range)
Btu/h
31420 - 65570 40300 - 80595 52082 - 104165
Rated max. heat input
Q
n
Btu/h
74450
92210
117825
Rated min. heat input
Q
min
Btu/h
36200
46105
58912
Supply pressure:
Natural gas 
mbar (kPa)
20 (2.0)
20 (2.0)
20 (2.0)
LPG (butane/propane) 
mbar (kPa)
28 (2.8)
28 (2.8)
28 (2.8)
Consumption:
Natural gas 
m
3
/h
2.2
2.77
3.5
LPG (butane/propane) 
kg/h
1.75
2.2
2.79
Number of injectors
12
14
18
Max. water pressure**
p
w
psi
170
170
170
Temperature control at maximum setting
Temperature increase
°C
50.0
50.0
50.0
Flow rate
l/min
5.5
7
8.8
Min. operating pressure
p
wmin
psi
2.0
2.0
3.0
Temperature control at minimum setting
Temperature increase
°C
25
25
25
Flow rate
l/min
11
14
17.6
Draught requirement
mbar
0.015
0.015
0.015
Flow rate
g/s
13
17
22
Temperature
°C
160
170
180
O
ut
pu
t a
nd
 h
ea
de
m
an
d
G
as
 s
u
pp
ly
 
sp
ec
ifi
ca
tio
ns
 *
W
at
er
 s
ys
te
m
 s
pe
ci
fic
at
io
ns
Fl
ue
 
sp
ec
ifi
ca
tio
ns
**
*