Bosch W14B User Manual

Page of 8
6 720 607 527 ZA (05.02) JS
W11..B...
W14..B...
W18..B...
With electronic ignition and triple safety system
consisting of ionisation detector, flue gas monitor
and heat exchanger temperature sensor.
Safety instructions:
If you smell gas:
- Do not operate any electrical switches.
- Do not telephone from inside the danger area.
- Turn off the gas cock.
- Open windows and ventilate room.
- From outside, call the gas company and your approved
installer.
Do not use or store easily combustible materials in the vicinity
of the appliance.
Gas Instantaneous Water Heater
Installation and Operating Instructions
Installation and servicing of the appliance may only be
carried out by an approved technician.
The appliance should be regularly serviced in order to ensure
that it remains in perfect and safe working order.
If there is a risk of freezing, the appliance must be switched
off and drained. If the appliance has not been drained during
a cold spell, when it is switched on again check that it
produces hot water. If problems occur, contact your installer