INTRODUCTION 
This ECS’s remote control system was developed to provide a safe, reliable, and user-friendly remote control system for gas heating 
appliances.  The system can be operated thermostatically or manually from the transmitter.  The system operates on radio frequencies 
(RF) within a 20'’range using non-directional signals.  The system operates one of 1,048,576 security codes that are programmed into 
the transmitter at the factory; the remote receiver’s code must be matched to that of the transmitter prior to initial use.  
 
 
 
 
 
WALL MOUNT THERMOSTAT 
 
The wall/transmitter operates on (2) 3V Button Cell (Included)  which  powers the LCD screen and 
powers the RF signal. These batteries are made specifically for remote controls and electronic 
lighters.  Before using the transmitter the  3V batteries must be installed into the battery 
compartments.   
 
It is recommended that CR2032 lithium batteries always be used for longer battery life and 
maximum operational performance.   
 
 
Upon initial use, there may be a delay of five seconds before the remote receiver will respond to 
the transmitter.  This is part of the system’s design.  If the LCD screen will not come on, check the 
3V Button Cell battery. 
 
 
 
 
 
 
 
TO INSTALL BATTERIES IN THE WIRELESS THERMOSTAT 
1. 
Remove face from backing plate This is done by sliding the face up about 1/2” then pull the face off the base plate. As shown 
in Figure #1 
2. 
Locate the (2) holders for the 3V button cell batteries. 
3. 
Slide the button cell batteries into the battery holders. (Make sure that the batteries are installed with the (+) plus side facing 
you or up. 
 
TO REMOVE THE BATTERIES IN THE WIRELESS THERMOSTAT 
1. 
Remove face from backing plate This is done by sliding the face up about 1/2” then pull the face off the base plate. As shown 
in Figure #1 
2. 
Locate the (2) holders for the 3V button cell batteries. 
3. 
Insert a small screwdriver into the slot above the button cell battery and push the battery out. AS shown in Figure #2 
 
Figure #1 
 
 
 
 
Figure #2 
 
 
 
 
 
 
 
 
 
Review COMMUNICATION SAFETY SECTION under TRANSMITTER section and THERMO SAFETY SECTION under REMOTE 
RECEIVER section.  These signal/temperature safety features shut down the fireplace system when a potentially unsafe condition exists.
 
IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION INSTRUCTIONS DO NOT 
ATTEMPT TO INSTALL OR OPERATE  
BACK OF UNIT
(2) 3 Volt Button
Cell Batteries
Battery Removal
Slots
  +
Plus
Side
  +
Plus
Side
 
ECS
 
ROOM
TEMP
THERMO
  MODE
“SET”
ON
SET
OFF
LCD
DISPLAY
ON/UP
BUTTON
OFF/DOWN
BUTTON
SET
BUTTON
ECS
 
ROOM
TEMP
ON
OFF
SET
ECS