13. SETTING METHOD FOR STANDARD DEPRESSION STROKES 
141 
13
. SETTING METHOD FOR STANDARD DEPRESSION STROKES 
 DANGER 
Wait at least 5 minutes after turning off the power switch and disconnecting the power cord from the wall outlet 
before opening the face plate of the control box. Touching areas where high voltages are present can result in 
severe injury. 
 
Use the following procedure to set the operating positions for the depression stroke.
 
13
-. When using the G50 operation panel 
1
 
Signal setting entry 
 
 
 
 
 
 
 
 
(Press the power OFF switch, and then set DIP switch No. 4 to ON.) 
 
 
 
 
 
 
 
“PdFF x.xxx” will appear in the main 
display (1). (x.xxx indicates the depression 
voltage.) 
(While pressing the        key, press the power ON switch.)                               
 
 
Memorizing the maximum forward position 
 
 
 
 
 
 
“Pdnn x.xxx” will appear in the main 
display (1). 
 
(With the treadle depressed forward to the maximum forward position,  
press the thread trimming key.) 
Memorizing the neutral position 
 
 
 
 
 
"Pdrr x.xxx" will appear in the main 
display (1).
 
 
 
(With your foot released from the treadle, press the thread trimming key.) 
 
Control box
 
2104B 
  2105B  2138M 
2106B 
2107B