Warning! 
Before replacing the rear panel fuse, disconnect the unit from the supply. Failure to 
do this may expose hazardous voltages. Unplug the unit from the local supply 
socket. 
1.  Ensure that power is turned off and the power cable is disconnected from the 
AC power inlet. 
2.  Ease out the fuse carrier by placing a small, flat-bladed screwdriver in the notch 
at the top of the carrier. 
Caution... 
When replacing the power input fuse, always ensure that a fuse of the correct type 
and rating is fitted. Failure to do so may result in inadequate protection. 
3.  Replace the fuse in the carrier. 
4.  Insert the fuse carrier back in the AC power inlet. 
 
 
Fuse Carrier 
To access the fuse, ease out 
the notch with a small flat-
blade screwdriver. 
 AC Power Inlet 
Figure 7.1   Fuse Carrier 
If the replacement fuse also blows, do not continue. Disconnect the equipment and 
contact Ericsson Customer Services (see Preliminary Pages) for advice. 
7.4.5 
Power Supply Problems 
Warning! 
Do not attempt to service the Power Supply Unit as opening or removing covers 
may expose dangerous voltages or other hazards. Refer all servicing to service 
personnel who have been authorized by Ericsson. 
Use the following techniques to fault-find according to the observed symptom(s) 
when a power supply failure is suspected. 
EN/LZT 790 0005 R1A
  
 
 
 