Ericsson RX8000 User Manual

Page of 236
Annex B 
 
 
B.7 
Power Supply – AC Mains Input 
This equipment is fitted with a wide-ranging power supply. It is suitable for supply 
voltages of 100-240 V AC -10% +6% at 50/60 Hz nominal.  
Table B.25  AC Power Supply Specification 
Item Specification 
Power distribution system 
Type TN ONLY (EN 60950-1 Annex V): Power distribution 
system which is directly earthed, the parts of the equipment 
required to be earthed being connected by protective 
earthing conductors. This equipment must NOT be used 
with single-phase three-wire and PE, TT or IT Type Power 
distribution systems. 
Connection to supply 
Pluggable Equipment Type A (EN 60950-1 para 1.2.5): 
Equipment which is intended for connection to the building 
power supply wiring via a non-industrial plug and 
socket-outlet or a non-industrial appliance Coupler or both. 
Correct mains polarity must always be observed. Do not 
use reversible plugs with this equipment. 
Class of equipment 
Class I Equipment (EN 60950-1 para 1.2.4): electric shock 
protection by basic insulation and protective earth. 
Rated voltage 
100-240 V AC (single phase) 
Rated frequency 
50/60 Hz 
Voltage selection 
Wide-ranging 
Rated current   
RX83xx: 1 A (100-240 V AC range) 
RX82xx: 1.5 A (100-240 V AC range) 
Input connector 
CEE 22/IEC 3-pin male receptacle 
Fuse 
Fuse in live conductor in power input filter at rear of unit. Do 
not use reversible plugs with this equipment. 
Fuse type 
Bussmann S505 
Littelfuse 215 
5x20 mm time delay (T) 1500 A breaking capacity (HBC) 
IEC/EN 60127-2 Sheet 5 
Fuse current rating 
All RX8000 models: 2  A  250 V  T  HBC 
Power consumption 
 
45 W typical (NO options fitted) 
60 W maximum 
B.8 
Cable Types 
The signal cable types (or similar) in Table B.26 are those recommended by 
Ericsson in order to maintain product EMC compliance.  
 
EN/LZT 790 0005 R1A
 
B-20