Electro-Voice NetMax N8000 User Manual

Page of 48
41
NetMax N8000 System Controller
Owner’s manual / Bedienungsanleitung
6.1 Specifications/Technische Daten
GENERAL DESCRIPTION AND FEATURES
N8000 System Controller
Modular NetMax system manager including signal proces-
sing, routing, system control and supervision
Audio
32 Audio Channels
4 Audio Slots, modular
8-Channel Input and Output cards, analog or digital
Networking
Module Slot for optional CobraNet™ Interface
32 I/O Audio and Control
Safety / Redundancy
Internal Supervision, System Monitoring, Watchdog, Fault
Output, Redundant Audio Network possible
PC Configuration and Control Software
IRIS-Net - Intelligent Remote & Integrated Supervision
Integration of N8000, Remote Amplifiers, peripheral control 
Configuration, Control and Supervision for complete Audio
Systems
Freely programmable User Control Panels and Access Le-
vels
AUDIO SPECIFICATIONS
Audio Inputs - Analog Input Module AI-1
8 analog audio inputs per module, line level, electronically
balanced
   Connectors
8 x 3-pole Euro block connectors
   Input Level (nominal)
+6 dBu / 1.55 V
   Input Level (max. before clip)
+21 dBu / 8.7 V
   Input Impedance
20 k
Ω
   Common Mode Rejection
> 70 dB
   A/D Conversion
24 Bit, Sigma-Delta, 128 times oversampling
Audio Outputs - Analog Output Module AO-1 8 analog audio outputs per module, line level, electronically
balanced
   Connectors
8 x 3-pole Euro block connectors
   Output Level (nominal)
+6 dBu / 1.55 V
   Output Level (max. before clip)
+21 dBu / 8.7 V
   Output Impedance
100 
Ω
   Min. Load Impedance
600 
Ω
   D/A Conversion
24 Bit, Sigma-Delta, 128 times oversampling
Frequency Response
20 Hz...20 kHz (-0.5 dB)
Signal to Noise Ratio (A-weighted)
AI-1: 117 dB typical
AO-1: 118 dB typical
N8000 analog In to analog Out: 115 dB typical
THD+N
< 0.005 %
Signal Delay
AI-1: 1.3958 ms
AO-1: 0.646 ms
N8000 analog In to analog Out: 2.2917 ms
Crosstalk
< -110 dB @ 1 kHz