Brother KE-434B User Manual

Page of 198
8. ELECTRIC MECHANISM 
 
KE-430B, 430C series
 
152
 
Initial value 
Switch 
Motion when set to ON 
Solenoid
Pneumatic
memo-15 
When using the inner clamping device, shunting to prevent interference 
between the inner clamping device and the needle is not carried out after the 
sewing end. 
-- 
-- 
memo-16 
Needle cooler can be used (available by special order). 
-- 
-- 
memo-17 
Thread take-up device is not operated at the sewing end. 
-- 
-- 
memo-18 
Thread take-up device operates one stitch before the sewing end. 
-- 
-- 
memo-19 
For solenoid specifications, presser position errors are not detected. 
-- 
-- 
memo-1A 
Needle up stop position errors are not detected. 
-- 
-- 
memo-1b 
Work clamp can be moved up and down before the home position is detected. 
(Normally the work clamp cannot be moved up and down until after the home 
position has been detected.) 
-- -- 
memo-1c - 
-- -- 
memo-1d 
For pneumatic specifications, the air pressure detection switch is enabled. 
(The air pressure sensor is a special-order option.) 
-- -- 
memo-1E 
Errors can be reset using the EMERGENCY STOP switch. 
(EMERGENCY STOP switch is available as an option except for KE-434*, 
435*, 484C.) 
-- -- 
memo-1F 
Thread is not trimmed when an emergency stop occurs during sewing. 
(EMERGENCY STOP switch is available as an option except for KE-434*, 
435*, 484C.) 
-- -- 
 
 
<Memory switches 20 - 2F> 
Initial value 
Switch 
Motion when set to ON 
Solenoid
Pneumatic
memo-20 - 
-- -- 
memo-21 
Rotating-type thread breakage detector operates. (Device is available by 
special order.) 
-- -- 
memo-22 
When thread breakage detection is operating, sensitivity is decreased at the 
sewing start. (Sensitivity during sewing is three stitches.) 
[Rotating-type] 8
14 stitches, [Fiber-type] 510 stitches 
-- -- 
memo-23 
When DIP switch A-8 is simultaneously ON, setting values changed using the 
operation panel are ignored. 
-- -- 
memo-24 - 
-- -- 
memo-25 - 
-- -- 
memo-26 
Enables the fiber-type thread breakage detector (when memo-21 is ON) 
-- 
-- 
memo-27 
Test operation of pneumatic-type thread trimmer, tension release and thread 
take-up. (KE-484C) 
-- -- 
memo-28 
Stores the amount of parallel movement in memory. 
(Use the memory all clear operation to clear the setting.) 
-- -- 
memo-29 
Pneumatic thread wiper sensor is enabled (when memo-12=ON and 
memo-14=ON) (sensor is optional). (KE-484C) 
-- -- 
memo-2A 
Special emergency stop release method is used (error code E-11 is cleared by 
pressing reset switch once and home position is cleared). (KE-484C) 
-- -- 
memo-2b 
memo-2E 
-- -- 
memo-2F 
Pneumatic thread wiper and work clamp operate together. (KE-484C) 
-- 
--