GE C11 User Manual

Page of 98
-1- 
  
Safety Instructions
 
Read this operation manual carefully and familiarize yourself with the operation of the drive be-
fore installation, connection (wiring), operation or maintenance and inspection of the device.  Be 
familiar with the drive, safety information, and safety signs before using the drive. 
In this instruction manual, safety signs are classified into the following categories.
 
 
 
 
 
!
WARNING 
 
Improper operation may result in death of serious injury.
 
 
 
 
!
CAUTION
 
Improper operation may result in slight to medium injury or property damage. 
 
Note:  More serious situations than those covered by the CAUTION sign can result depending on 
the circumstances. It is important that you always follow the instructions 
 
Compliance with UL/cUL standards [Applicable to products with UL/cUL mark] 
 
 
 
!
CAUTION
 
1.  [WARNING] Take care of electric shock. Be sure to turn the drive off before starting work. 
2.  [CAUTION] When the charge lamp is lit, the drive is still charged at a dangerous voltage. 
3.  [WARNING] There are two or more live parts inside the drive. 
4.  The drive is approved as a part used inside a panel. Install it inside a panel. 
5.  Perform wiring to the input, output and control terminals of the drive, referring to the table below. 
Use UL certified round crimp terminal to the input and output terminals with insulation cover or 
covered with reduced tube to obtain the insulation distance. Use a crimping tool recommended 
by the terminal manufacturer when fabricating crimp terminals. 
6.  Install a fuse in the power supply to the drive, referring to the table below. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1)  Only the L1/L and L2/N phases are provided for the single-phase 230V input series. 
2)  Use copper wires of allowable maximum temperature 60 or 75 °C
3)  Use UL certified "fast acting fuse." 
Connect the power supply satisfying the characteristics shown in the table below as an input power supply 
of the drive. (Short circuit rating)
 
 
 
Tightening torque  
Lb • Inch[N • m] 
Applicable wire diameter 
[AWG] (mm
2
)
2)
 
Recommended fuse 
Voltage 
Drive type 
L1/R, L2/S, L3/T
 
1)
 
U. V. W 
Control 
section 
L1/R, L2/S, L3/T
 
1)
 
U. V. W 
Control 
section 
Fuse 
[A] 
3)
 
Gould   
Company  
Bussmann 
Company  
6KC1123F12X1** 
A4J3 
JKS3 
6KC1123F25X1** 
A4J6 
JKS6 
6KC1123F50X1** 
10 
A4J10 
JKS10 
6KC1123001X1** 
15 
A4J15 
JKS15 
6KC1123002X1** 
14 (2.1) 
20 
A4J20 
JKS20 
6KC1123003X1** 
10.6 (1.2) 
12 (3.3) 
30 
A4J30 
JKS30 
3
-phase 230V input
 
6KC1123005X1** 
15.9 (1.8) 
10 (5.3) 
40 
A4J40 
JKS40 
6KC1121F12X1** 
A4J6 
JKS6 
6KC1121F25X1** 
A4J6 
JKS6 
6KC1121F50X1** 
10 
A4J10 
JKS10 
6KC1121001X1** 
14 (2.1) 
15 
A4J15 
JKS15 
6KC1121002X1** 
10.6 (1.2) 
12 (3.3) 
30 
A4J30 
JKS30 
Single
-phase 230V 
input
 
6KC1121003X1** 
15.9 (1.8) 
3.5 
(0.4) 
10 (5.3) 
20 
(0.5) 
40 
A4J40 
JKS40 
Drive type 
Input max. volta 
 Input current  
3 Phase input  
AC230V 
Single phase input  
AC240V 
5,000 A or less