• A fan may have failed. Most fans are sensed. That means the electronics module 
knows whether they are running or not. If they don’t run when they should, the 
electronics module turns off the lamp and prevents it from striking (turning on) again.
Swapping other parts: You can swap electronics modules or fans in the same way to 
see if one is bad.
Why not use a new part out of the box? It may seem like a good idea to take a new 
part out of the box and substitute it for a suspected part in the display. However, there is 
a small chance that the part in the box doesn’t work. If you test a part by putting in a 
known good part, you get better information.
When you swap fans, always exchange fans of the same size.
Note