Sony PDW-R1 User Manual

Page of 155
Chap
te
r 7
  
 Men
u
s
99
7-3 Extended Menu
258
LIVE LOGGING
Enable or disable the live logging function when using the PDZ-1 Proxy 
Browsing Software.
off: Disable.
on: Enable.
Note
During live logging, regardless of the settings of the switches (INT/EXT/
RP188, PRESET/REGEN, and F-RUN/R-RUN) in the time data settings 
section, the internal time code generator always runs in free run mode. 
Time code cannot be recorded in internal preset mode. 
Menu items in the 200s, relating to the remote control interface
Item number
Item name
Settings
Menu items in the 300s, relating to editing operations
Item number Item name
Settings
308
SELECTION OF STD/NON-STD 
FOR COMPOSITE VIDEO IN
Select the STD or NON-STD mode in accordance with a composite 
video or S-video input.
STD (forced STD): The STD mode is always used (forced STD mode).
N-STD (forced non-STD): Use this setting when the input video signal is 
unstable (forced NON-STD mode).
Note
When using a VCR with no built-in time base corrector (e.g. a home-use 
VHS-system VCR), select N-STD.
310
REC INHIBIT
Select whether recording is inhibited.
off: Do not inhibit recording.
on: Inhibit recording.
320
DIGITAL AUDIO PB PROCESS ON 
EDIT POINT
Select the treatment of audio playback at edit points.
cut: Carry out a cut (possibly resulting in audio discontinuities at the edit 
point).
fade: Fade out and fade in.
335
OUTPUT REFERENCE SEL
Select the reference signal of this unit.
ref (ref. video): Use the signal input to the REF VIDEO IN connector as 
the reference signal. 
auto: According to the operation mode, automatically select either the 
signal input to the REF VIDEO IN connector or the input video signal 
selected with the VIDEO INPUT SEL button as the reference signal.
The input digital audio signals and video signals must be synchronized 
with the reference signal input to the REF VIDEO IN connector.