Nilfisk Alto 7309021 User Manual

Page of 56
44
3.5.1   Setting of water temperature
The knob for adjusting the water temperature is placed on the steering A1 in the switchboard 
and  may either be put in the 
OFF position (click function - vertically) or set on the desired 
mixing temperature. The yellow diode below the control knob indicates the starting point of the 
temperature adjustment.
 
OFF
In this position the system will allow the parallel inlet of water from the two water connections 
into the water tank. This is an advatage if the pressure of the inlet water is low and you can do 
without the function of temperature regulation.
No adjustment of temperature is provided for, but the water temperature at the two connections 
may be selected freely (lower than 75°C). 
The yellow indicator symbol  
  on the control panel (section 3.6, Fig. 5, symbol 4) is not lit.
 
ON  
 
50°C
In this position water from the two connections will be mixed to the desired mixing temperature 
(e.g. 50°C).
The yellow indicator symbol 
 on the control panel (section 3.6, Fig. 5, symbol 4) will glow 
constantly as an indication that the temperature adjustment has been activated.
The indicator lamp may start to flash while the system is in operation. This means that the tem-
perature adjustment has been cancelled by the controls. This will happen if the water supply 
from either the cold or the hot connection is so sparse (closed tap, low water pressure) that the 
system is about to enter to a fault situation:
 “Lack of water”.
Both connections will then be opened in parallel until a high water level has been achieved. The 
attempt at mixing to the desired temperature will then be repeated.
The indicator lamp will continue to flash even though the water supply returns to OK and the 
temperature adjustment is repeated.
Please note: The flashing can only be removed by restarting the system.