A.0500.551 – IM-TGMAG/02.00 EN (02/2008)
T-jacket on pump cover
3.  Jacket on pump cover 
In case of steam supply, connect the supply line at the highest position and the return line 
to the lowest position so that condensed water will be drained via the lowest line. In case of liquid 
supply, the positions are not important. A drain plug Bh is provided and can be considered as a drain 
line.
4.  Jackets on safety relief valve – around spring casing
The jackets on the safety relief valve are designed for  
use with saturated steam (max 10 bar, 180°C) or with  
non-dangerous media. They are provided with threaded  
connections Bo (see chapter 6.0 for dimensions).  
The connection can be done by threaded pipes or pipe  
connections with sealing in the thread (conical thread 
applying ISO 7/1). Thread type see section 3.21.7.
3.18.7  Guidelines for assembly
When a bare shaft pump is delivered, the assembly with drive is the responsibility of the user. 
The user also must provide all necessary devices and equipment allowing a safe installation and 
commissioning of the pump.
3.18.7.1  Transport of pump unit
•  Prior to lifting and transporting a pump unit, make sure that the packaging is of sturdy enough 
construction and will not be damaged during transport.
•  Use crane hooks in the baseplate or the frame. (See chapter 1.0.)
3.18.7.2  Foundation pump unit
The pump unit must be installed on a base plate or on a frame placed exactly level on the  
foundation. The foundation must be hard, level, flat and vibration free in order to guarantee  
the alignment of pump/drive while operating. (See section 3.18.2.5)
3.18.7.3  Variators, Gear box, Gear motors, Motors
Consult the suppliers’s instruction manual , included with the delivery. Contact the pump supplier if 
the manual is not included.
3.18.7.4  Electric motor drive
•  Before connecting an electric motor to the mains check the prevailing local regulations of your
electricity provider as well as the EN 60204-1 standard.
•  Leave the connecting of electric motors to qualified personnel. Take the necessary measures to
prevent damage to electrical connections and wiring.