4-2-4. Configuration of Test Mode
Note:
*1) on the set
*2) on the remote commander
*3) on the set or remote commander
4-3. MANUAL MODE
Mode to adjust or check the operation of the set by function.
Normally, the adjustment in this mode is not executed.
• Transition method in Manual Mode
1. Setting the test mode. (See page 13)
2. Press the
>
or 
[VOL +]
 key activates the manual mode
where the LCD display as shown below.
3. The optical pick-up moves outward or inward while
the
>
or
.
key is pressed for several seconds respec-
tively.
4. Each test item is assigned with a 3-digit mode number;
100th place is a major item, 10th place is a medium item, and
unit place is a minor item.
[Manual Mode]
[Servo Mode]
[Audio Mode]
[Power Mode]
[OP Alignment Mode]
[Overall Adjustment Mode]
[Self-Diagnosis Display Mode]
Press the  
>  
*
1)
 or 
[VOL +]
 *
3) 
key
[Key Check Mode]
[Test Mode $Display Check Mode%]
Press the  
 *
3)
 key
Press the  
 *
3)
 key
Press the  
 *
3)
 key
Press the  
 *
3)
 key
Press the  
.  
*
3)
 or 
[VOL --]
 *
3)
 key
Press the  
N
  *
1)
 or 
[REC]
 *
1)
 or  
N >   
*
2)
 key
press the 
[DISPLAY]
 
*
2)
 or   MENU 
.
  
*
1)
 key 
Press the 
[T MARK]
 *
3)
 or 
[DISPLAY]
 *
2)
 key 
on the remote commander for several seconds.
Quit the key check or open the upper panel
[Sound Skip Check Result  Display Mode]
LCD display
M a n u a l
000
[VOL +]
 key:100th place of mode number 
increase.
[VOL --]
 key:100th place of mode number 
decrease.
[Major item switching]
[VOL +]
 key:10th place of mode number 
increase.
[VOL --]
 key:10th place of mode number 
decrease.
[VOL +]
 key:Increases the 
adjusted value
[VOL --]
 key:Decreases the 
adjusted value
[Medium item switching]
 
 key
 
 key
[Minor item switching]
[Adjusted value variation]
 key: When adjusted value is 
changed:
Adjusted value is written.
When adjusted value is 
not changed:
That item is adjusted 
automatically.
[Adjusted value write]
 
 key
 
 key: Unit place of mode number 
increase. 
 
 key