Perform the settings for the recording schedules of record-
ing and event action by designating a day of the week and
time.
A day can be divided into up to 6 time zones, and record-
ing programs and event action programs can be assigned
to each time zone to create a recording schedule.
Up to 4 normal recording programs (REC Program) and up
to 4 event action programs (Event Program) can be creat-
ed. Perform the settings for the REC Program: resolution
and recording rate. Perform the settings for the Event
Program: action mode for each event type and auto copy.
It is possible to create special days apart from the normal
schedule, and a recording program of another day of the
week can be switched to a special day’s program automati-
cally.
Flowchart on how to create a schedule
Follow the procedures below to create schedules.
Create REC Program/Event Program. 
(aPage 119 and 120)
Create a timetable. (aPage 121)
Assign REC Program/Event Program to a timetable.
(aPage 121)
● [REC Program] Create a recording program 
Perform the settings of resolution, and the settings of
recording rate and image quality for each camera channel.
Up to 4 recording programs can be created.
Resolution
FRAME 3D ON: High resolution (720 x 480) with the motion
blur compensation
FRAME 3D OFF: High resolution (720 x 480)
FIELD: Standard resolution (720 x 240)
SIF: Low resolution (360 x 240)
Note: When "FRAME 3D ON" is selected, it is possible to
record a moving object with less blurring. However,
fuzzy images may sometimes be displayed. 
Important:
• In the following cases, recording will not be performed
for around 4 seconds:
• When resolution is switched such as when a differ-
ent resolution is set depending on different time
zones
• When the SETUP MENU is closed after changing
the settings
Recording Rate and Image Quality for Each
Camera Channel
Perform the settings for recording rate, image quality and
recording duration for each camera channel (The settings
for recording duration can be performed only for pre-event
recording and post-event recording.).
OFF/0.1 ips/0.2 ips/0.3 ips/0.4 ips/0.5 ips/1 ips/2 ips/
3 ips/5 ips/6 ips/7.5 ips/10 ips/15 ips/30 ips/60 ips
Important:
• When the total of the recording rate of camera channels
1 - 16 is set to the maximum (60 ips when FIELD is
selected, 120 ips when SIF is selected), the recording
rate of two of the camera channels to which the lowest
and the second lowest recording rates are set will be
lower than the set recording rate. (When the lowest
recording rate is applied to three of the camera chan-
nels, this may happen to two of the three channels.)
• The maximum rate for each camera channel differs
depending on the resolution as follows.
FRAME 3D ON/FRAME 3D OFF: 30 ips
FIELD: 60 ips
SIF: 30 ips
• The total of the recording rates of camera channels
must be as follows. 
FRAME 3D ON/FRAME 3D OFF: 30 ips or less
FIELD: 60 ips or less
SIF: 120 ips or less
When the total recording rate becomes more than the
above values, the sections displaying the maximum record-
ing rates for each camera channel will turn red, and it will
be impossible to close the recording program window. In
this case, lower the recording rate that has turned red to a
value less than the above values.
The following are available for the image quality.
SFA/SFB: Top quality (SUPER FINE)
FQA/FQB: High quality (FINE)
NQA/NQB: Standard quality (NORMAL)
EXA/EXB: Low quality (EXTENDED)
**A is suitable for less dynamic images.
**B is suitable for more dynamic images.
The following are available for the recording duration (only
for event pre-recording and event post-recording).
1 s - 10 s (in 1 second intervals)
20 s/30 s/1 - 10 min (in 1 minute intervals)
20 - 60 min (in 10 minutes intervals) 
■ [Schedule] Settings for the recording/event action schedule
Event
Shedule
Maintenance
Display
Comm
Switcher
SETUP MENU
LIVE
System
Recording
Time Table
REC Program
Event Program
Special Days
Quick Menu
MON
TUE
WED
THU
FRI
SAT
SUN
EVERY
EXT.
12AM
6AM
12PM
6PM
12AM
REC:
P1
P2
P3
P4
EVT:
P1
P2
P3
P4
Advanced
■ 
Resolution
■ 
Recording Table
■ 
Total REC Rate
48 ips
60 ips
FIELD
Recording Program 1
O K
CANCEL
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
1ips
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
FQB
10s
10s
10s
10s
10s
10s
10s
10s
10s
10s
10s
10s
10s
10s
10s
10s
30s
30s
30s
30s
30s
30s
30s
30s
30s
30s
30s
30s
30s
30s
30s
30s
3ips
3ips
3ips
3ips
3ips
3ips
3ips
3ips
3ips
3ips
3ips
3ips
3ips
3ips
3ips
3ips
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
SCHEDULE
TIME
TIME
RATE
QUALITY
MANUAL
PRE EVENT
POST EVENT
RATE
QUALITY
RATE
QUALITY
RATE
QUALITY
CAM1
CAM2
CAM3
CAM4
CAM5
CAM6
CAM7
CAM8
CAM9
CAM10
CAM11
CAM12
CAM13
CAM14
CAM15
CAM16