Philips CDR796 User Manual

Page of 52
5-7
5-7
N
Y
KEY TEST 
Display shows
Numbers acc. table 2
are indicated as long as a
button is held depressed.
If a button is pressed
on the Remote Control
KEY RC
 is shown
and the 
;
 flag flashes.
CD
 
ALBUM -  button
pressed?
CD
 
STOP  button
pressed?
N
Y
10
SHUFFLE
INPUT
ALBUM -
(CDR)
PLAY/PAUSE
(CD)
SPEED
STOP
(CDR)
19
20
21
PLAY/PAUSE
(CDR)
RECORD
KEY
KEY CODE
2
3
4 (exit)
5
6
7
8
9
12
15
11
 
S
(CDR)
ALBUM +
(CDR)
14
13
16
17
ERASE CD
 
S
(CD)
STOP
(CD)
ALBUM -
(CD)
STANDBY
(CDR)
OPEN/CLOSE
(CD)
18
(CD)
1
0
ALBUM +
(CD)
DISPLAY
COPY CD
OPEN/CLOSE
(CDR)
KEY
KEY CODE
KEY CODES
table 2
SERVICE TESTPROGRAM
VARIOUS TESTS
CDR79x servtest various, 240402
N
Y
FORMAT EEPROM 
Display shows
for 2s.
EEPROM is cleared and
default values are stored.
SHUFFLE  button
pressed?
This test should only be used to clear
the EEPROM in case of a 
µ
P-"hangup".
Attention: all data are set to default values,
BLACK BOX data are not cleared.
KEY --
DISPLAY button
pressed?
STOP button
pressed?
N
N
Y
Y
Display shows
all segments and flags
for checking open circuits.
see figure 1
All LEDs are switched on.
DISPLAY TEST
fig. 1
N
Y
QUARTZ TEST 
Display shows
1220
±
37Hz can be measur.
on       (pin 23 of 
µ
P).
STOP  button
pressed?
N
Y
SPEED button
pressed?
Tact frequency 
µ
P
(divided 10MHz)
f
0
10M
NEW
V
XX
S
* To leave Service Testprogram plug mains cord off.
* In the main menu the sound settings (volume, ...)
and trays work as in normal mode. 
Display shows
version number 
of the 
µ
P - software.
stands for Service mode
stands for Version number
of the software used in the
Front (Display) 
µ
P.
To enter Service
Testprogram hold
PLAY & REC buttons
depressed while
plugging mainscord in.
S-CDR795-V
XX
N
Y
EXIT
END-USER DIAGNOSTICS
Display shows:
FAILED
for 3s.
Display shows:
PASSED
for 3s.
END-USER DIAGNOSTICS
(CDR module)
To enter
END-USER DIAGNOSTICS
hold 
buttons
on CDR side depressed
while plugging mainscord in.
TEST O.K.? 
Display shows for 5s each:
• Software version of set 
µ
P
S
 stands for Service mode
V
XX
 
stands for Version
number of the software used
in the Front (Display) 
µ
P.
• Software versions of the
CDR module:
 
MOXXXX
 stands for
Software version of
MOZART flash ROM 7101
BXXXX
 stands for
Software version of
Basic Engine
flash EPROM 7017
SDRAM TEST 7100
Display shows:
DTST1
CHECKSUM TEST 7101
Display shows:
DTST2
ERASE TEST 7101
Display shows:
DTST3
COMMUNICATION TEST
(UART-BUS)
Display shows:
DTST4
S-CDR795-V
XX
MOXXXX BXXXX
NEW
Display shows
for 2s.
EEPROM is cleared
and default values
are stored.
PASS
N
Y
EEPROM TEST 
Display shows
ERR
Display shows
Testpattern is written to
address 1
and
 read back again
INPUT button
pressed?
STOP  button
pressed?
Test ok? 
N
Y
N
Y
NTC XX
N
Y
TEMPERATURE
(NTC) TEST 
Display shows
XX = value in 
°
C
STANDBY button
pressed?
STOP  button
pressed?
N
Y
STANDBY button
pressed?
N
Y
Fan is switched on/off
display shows
or
for 2s.
FAN ON
FAN OFF
STEP ALBUM
MP3
PLAYLIST
TOTAL
REM
REC
TRACK
TRACK
TIME
TIME
REP TRACK DISC ALL PROG SHUFF
CDTEXT
EDIT
CD RECORDER
L
R
CD PLAYER
8X
4X
2X
1X
LINE
DIG
OPTMIC
REC
CD
R W
FINALIZE
SERVICE TESTPROGRAM