McIntosh MCD301 User Manual

Page of 24
8
Installation
Installation
The MCD301 can be placed upright on a table or shelf, 
standing on its four feet. It also can be custom installed in 
a piece of furniture or cabinet of your choice. The four feet 
may be removed from the bottom of the MCD301 when it 
is custom installed as outlined below. The four feet togeth-
er with the mounting screws should be retained for possible 
future use if the MCD301 is removed from the custom 
installation and used free standing. The required panel 
cutout, ventilation cutout and unit dimensions are shown.
Always provide adequate ventilation for your MCD301. 
Cool operation 
ensures the 
longest pos-
sible operat-
ing life for 
any electronic 
instrument. 
Do not install 
the MCD301 
directly above 
a heat generat-
ing compo-
nent such as a 
high powered 
amplifier. If 
all the com-
ponents are 
installed in a 
single cabinet, 
a quiet running 
ventilation 
fan can be a 
definite asset 
in maintaining 
all the system 
components 
at the coolest 
possible oper-
ating tempera-
ture.
A custom cabi-
net installation 
should provide 
the follow-
ing minimum 
spacing dimen-
sions for cool 
operation.
Allow at least 2 inches (5.08cm) above the top, 2 inches 
(5.08cm) below the bottom and 1 inch (2.54cm) on each 
side of the SACD/CD Player, so that airflow is not ob-
structed. Allow 17 inches (43.18cm) depth behind the front 
panel. Allow 1-1/8 inch (2.9cm) in front of the mounting 
panel for knob clearance. Be sure to cut out a ventilation 
hole in the mounting shelf according to the dimensions in 
the drawing.
31%
02:38
.
  4-
7/8
"
12.38cm
17-
1/16
"
43.34cm
Cutout Opening for Custom Mounting
MCD301 Front Panel 
Custom Cabinet Cutout
  8
-5/8
"
21.91cm
 15
-1/2
"
39.37cm
15-
1/16
"
38.26cm
  1"
2.54cm
Cutout Opening
for Ventilation
Cutout Opening for Ventilation
Support
Shelf
Cabinet
Front
Panel
Chassis
Spacers
MCD301 Side View
in Custom Cabinet
MCD301 Bottom View
in Custom Cabinet
1-
1/16
"
2.70cm
12
-5/16
"
31.27cm
   3"
7.62cm
Note: Center the cutout Horizontally on the unit.