Omega Vehicle Security 1400 User Manual

Page of 273
3-18
ChartScan User’s Manual
CSN14/HV/S  
High Voltage Card with Safety Jack Connectors
The CSN14/HV/S card contains 16 differential input channels and is for use with “safety jack” type connectors. Each
CSN14/HV/S card is capable of measuring analog input signals on any of the following three programmable ranges:
±2.5 volt, ±25 volt and ±250 volt.
CSN14/HV/S,  High Voltage Card with Safety Jack Connectors
Number of Inputs:
16 differential; programmable by channel for input range
Input Connectors:
Safety Jack
Voltage Range, Accuracy and Resolution:
• 
± 2.5V;
± 0.02%;
78.14 
µV/bit
• 
± 25 V;
± 0.02%;
781.4 
µV/bit
• 
± 250 V;
± 0.02%;
7.81 mV/bit
Digital Filtering:
      Used for AC line cycle noise rejection.
      Selectable off, 1-256 samples in a binary count.
Temperature Coefficient:  
< 0.01%/°C
Input Impedance:  10 M
Ω typical
Input Bias Current:    20 pA maximum.
Maximum Common Mode Voltage:
1
  500 VDC or 500 VAC peak
Maximum Normal Mode Voltage: 500 VDC or 500 VAC peak
Common Mode Rejection:    100 dB typical.
Maximum Allowable Input:  500 VDC or 500 VAC peak
Channel-to-Channel Isolation:
                
500 VDC or 500VAC peak
Channel-to-Power Ground Isolation:
2
               500VDC or 500 VAC peak
Note 1: Specified for coupling impedance >30 M
Ω and common mode frequency < 60 Hz.  700 VDC or 700 VAC peak ; 325 VDC
or 325 VAC peak if used in the same system with a MTC/24 scanning module, before equipment damage occurs.
Note 2: 325 VDC or 325 VAC peak if used in the same system with a MTC/24 scanning module.