3com 3CB9LF36RL User Manual

Page of 60
Known Problems
37
The object a3ComSysBridgePortAddressStaticPort should return one 
of the following values:
The local bridge port index when a static address is configured for 
the port
The value 0 when a dynamic address is configured for the port
However, the 9-port 1000BASE-SX Gigabit Ethernet Layer 2 Switching 
Module returns the following reversed values:
The local bridge port index when a dynamic address is configured 
for the port
The value 0 when a static address is configured for the port
If there is a trunk on the switching module, an SNMP getnext request 
on the MIB object a3ComTrunkTcmpMacState incorrectly returns the 
first instance of this object. For example, a Gigabit Ethernet switching 
module that is located in slot 6 has two trunks:
Ports 1 and 9 — MIB objects a3ComTrunkTcmpMacState.14.1 and 
3ComTrunkTcmpMacState.14.9
Ports 4 and 5 — MIB objects a3ComTrunkTcmpMacState.15.4 and 
3ComTrunkTcmpMacState.15.5
The objects in the a3ComTrunkMacTable are not accessible via SNMP.
Through SNMP the object a3ComSysEthernetPortRequestedPortMode 
can be set to values out of range for the port, only use the values that 
are for 10 or 100. (30022)
Ethernet
The following Ethernet statistics are not reset after you enter the 
module baseline set
 command:
rxPeakFrameRate
txPeakFrameRate
rxPeakByteRate
txPeakByteRate
If a bridging loop exists on a switching module or switch fabric 
module, output from the
 ethernet detail 
command can take up to 
30 minutes to display. This issue does not apply to the 36-port 
10/100BASE-TX Desktop Switching Modules (Model Numbers 
3CB9LF36RL and 3CB9LF36TL). (30080)