Toshiba DK14 Developer's Guide

Page of 418
System & Station
Program 03 for DK40i – Flexible PCB Slot Assignments
3-4
Strata DK Programming
5/99
Program 03 for DK40i – Flexible PCB Slot Assignments
Processor Type:
DK40i
Program Type:
System
Initialized Default:
PCB codes of PCBs installed prior to running Program 91-1 or Program 91-9
Code 00 for empty slots (15~18), Base KSU has codes for PCBs

 

  6SNU   +ROG  6SNU
+ROG 
Turn System Power OFF (5 sec) then ON
PCB Code Reference Table
PCB Fixed Slot
Code
Ports/Type
Common Control
91
None
Common Control w/K4RCU3
92
4 DTMF/ABR
Common Control w/K5RCU 
or K5RCU2
98
5 DTMF/ABR
PIOU/PIOUS/RSSU/PEPU
41
None
PEKU
21
8 EKT
PEKU with EOCU
22
8 EKT
PEKU with DSS
23
8 EKT
PEKU with EOCU, DSS
24
8 EKT
PESU
25
2 SLT/4 EKT
PESU with EOCU
26
KSTU2/RSTU2/Stratagy DK
31
4 SLT/8 SLT/
8VM
TCOU/PCOU/RCOU/RGLU2
11
4/CO
RCOU + RCOS
17
8 Loop CO
Base Unit DKT CKTs, PDKU, 
and RWIU
61
8 DKT
Base Unit DKT CKTs 
& PDKU w/ DIU 
or SP-OCA
62
8 DKT
Base Unit DKT CKTs and 
PDKU with DSS (w/ or w/o 
DIU or SP-OCA)
64
8 DKT
KCDU
65
2/CO, 4 DKT
KCDU SP-OCA or DIU
66
2/CO, 4 DKT
RDSU (RSTS)
27
4 DKT/4 SLT
RDSU (RSTS) with DIU or 
SP-OCA
28
4 DKT/4 SLT
RDDU/TDDU
16
4 DID Lines
REMU 13
4-Tie 
Lines
RCIU2/RCIS/TCIU2
81
4 or 8 Caller ID
TBSU or RBSU
77
2 BRI S/T
RBSU/RBSS
78
4 BRI S/T
TSIU
No Code Required
None
00
None
more codes
...or
Run Program 91-2
SELECT = Slot Number (00, 11~18)
CARD = PCB Code (See Reference Table)
DK40i Base KSU
DK40i Expansion KSU
TMAU2
DKU
TBSU,
TCOU
or TDDU
KSTU2
TCIU2
Slot Number
00
11
12
13
14
PCB Code
91, 92 or
98
62 
or 
64
00, 11, 
16, or 77
00 
or 
31
00 
or 
81
PCB Type
Options
Station/BRI 
Port Numbers
CO/DID/BRI 
Line 
Numbers
Cabinet Label
04
05
06
07
Slot Number
15
16
17
18
PCB Code
PCB Type
Options
Station/BRI 
Port Numbers
CO/Tie/DID/BRI 
Line Numbers
 
Notes
For systems containing ISDN PCBs, immediately after running 
Program 03, make sure to run Program *60 to identify all station 
(NT) and CO (TE) BRI circuits for each RBSU/RBSS and TBSU 
installed. Program *60 causes station port and CO line shifting on 
PCBs installed in higher slots that follow the BRI PCBs.
Consult DK40i configuration section to check that the DK40i is 
configured properly.