Explanation: Tape reader task number ‘nnn’ has terminated processing in
response to an operator command, or following an unrecoverable
error condition.
error condition.
Action: None. This is an informational message.
OTD25011
Return code xx Supp codes X'yyyyzzzz' received opening | reading |
closing d/b dddd, T=Tnnn
closing d/b dddd, T=Tnnn
Explanation: An error has been received by tape reader task ‘nnn’ accessing the
Archive Manager database with identifier ‘dddd’, for the type of
processing identified in the message. ‘xx’ gives the return code
received from the Archive Manager call, and ‘yyyy’ and ‘zzzz’ give
supplementary error codes 1 and 2. Processing of the current request
is terminated with an error.
processing identified in the message. ‘xx’ gives the return code
received from the Archive Manager call, and ‘yyyy’ and ‘zzzz’ give
supplementary error codes 1 and 2. Processing of the current request
is terminated with an error.
Action: Refer to the Archive Manager User Manual for an explanation of the
return and supplementary codes displayed in the message. Take the
appropriate corrective action and re-submit the request.
appropriate corrective action and re-submit the request.
OTD25012
Unrecoverable error condition - tape reader task nnn terminating
Explanation: An error condition has been encountered during processing of a
request by tape reader task ‘nnn’, and the task is unable to recover.
The request will be terminated with an error condition and the reader
task will terminate. The value of the MAXTRDR initialization
parameter will be automatically decremented by 1.
The request will be terminated with an error condition and the reader
task will terminate. The value of the MAXTRDR initialization
parameter will be automatically decremented by 1.
Action: Examine the system log for other DB2 Manager messages giving
information about the original error condition. Take the appropriate
corrective action and re-submit the failing request. To restart the
terminated reader task, set the value of MAXTRDR to its value prior to
termination of the task.
corrective action and re-submit the failing request. To restart the
terminated reader task, set the value of MAXTRDR to its value prior to
termination of the task.
OTD25013
Error xx received writing SMF record
Explanation: An error has been detected by a tape reader task writing a record to
the SMF dataset. ‘xx’ gives the return code received from the
SMFWTM macro. Tape reader task processing will continue
normally.
SMFWTM macro. Tape reader task processing will continue
normally.
Action: Refer to IBM documentation for an explanation of the return code
displayed in the message. Take the appropriate corrective action to
resolve the problem.
resolve the problem.
OTD25040 System abend ‘xxx’ intercepted – control region will attempt to
recover
Explanation: A system abend condition has occurred during tape reader task
operation, and has been intercepted by the program. The tape
reader task will attempt to recover from this condition and continue
processing normally.
reader task will attempt to recover from this condition and continue
processing normally.