Hague Quality Water Intl LC100 User Manual

Page of 48
RO Specifications 
Model Part # 
H2000 
2056U 
H2500 
2256U 
H3000
1
3146U 
H3500
1
2246U 
LC 30 
N/A
LC 50/50P
N/A
LC 100/100P
N/A
Membrane
CTA
CTA
TFC
TFC
TFC
TFC
TFC
Production Rates 
Gallons per day
2
Liters per day
2
WQA GPD
3
WQA LPD
3
16
60.5
N/A
N/A
16
60.5
N/A
N/A
N/A
N/A
13
49
N/A
N/A
13
49
30
50
N/A
N/A
50
189
N/A
N/A
100
378
N/A
N/A
Water Pressure  
(Min-Max) 
40–100
40–100
40–100
40–100
40–100
40–100
40–100
Water Temperature 
Degrees, F (Min-Max) 
40–85
40–85
40–113
40–113
40–113
40–113
40–113
Chlorine Tolerance 
(ppm)
0.5–1.5
0.5–1.5
0
0
0
0
0
Max. Hardness (Gr. pg) 
10
10
10
10
10
10
10
Max. Iron (ppm) 
< 0.1 
< 0.1 
< 0.1 
< 0.1 
< 0.1 
< 0.1 
< 0.1 
Max. Mang. (ppm) 
< 0.05 
< 0.05 
< 0.05 
< 0.05 
< 0.05 
< 0.05 
< 0.05 
pH Limit 
5.0–9.0
5.0–9.0
4.0–11.0
4.0–11.0
4.0–11.0
4.0–11.0
4.0–11.0
Max. TDS Limit (ppm) 
1200
1200
2000
2000
2000
2000
2000
Hydrogen Sulfide (ppm) 
0.00
0.00
0.00
0.00
0.00
0.00
0.00
Max. Turbidity (NTU) 
1.0
1.0
1.0
1.0
1.0
1.0
1.0
TDS Rejection 
Typical @ 60 psi 
WQA @ 50 psi 
95%-97% 
N/A
95%-97% 
N/A
N/A
96.7%
N/A
96.2%
97%–98%
N/A
97%–98% 
N/A
97%–98% 
N/A
Storage (Gal.) 
3.1
3.1
3.1
3.1
3.1
Optional
Optional
Water Supply 
Municipal,
Chlorinated
Municipal,
Chlorinated
Municipal,
Well, Non-
Chlorinated
Municipal,
Well, Non-
Chlorinated
Municipal,
Well, Non-
Chlorinated
Municipal,
Well, Non-
Chlorinated
Municipal,
Well, Non-
Chlorinated
Treatment Stages 3
3
5
5
5
4
4
4
4
Prefiltration
5 Micron 
Sediment
5 Micron 
Sediment
5 Micron 
Sediment,
GAC
1 Micron 
Sediment/
Carbon Block 
5 Micron 
Sediment,
GAC
5 Micron,
20
-inch
Sediment,
GAC
5 Micron,
20
-inch
Sediment,
GAC
PCF
N/A
N/A
Standard
Standard
Standard
N/A
N/A
Postfilter GAC
GAC
GAC
GAC
GAC
GAC
GAC
Height (inches) 
15 1/4 
15 1/4 
16 3/4 
16 3/4 
16 3/4 
28
28 3/4 
Width (inches) 
14 1/2 
14 1/2 
14 1/2 
14 1/2 
14 1/2 
14 1/2 
14 1/2 
Depth (inches)
7
7
7
7
7
7
7
Weight
29 lb 
29 lb 
35 lb 
35 lb 
35 lb 
38 lb 
40 lb 
Efficiency Rating
5
N/A
N/A
13% 17.9%  N/A
N/A
N/A
Recovery Rating
6
N/A
N/A
24% 21.4%  N/A
N/A
N/A
1
 H3000 and H3500 are certified by WQA to NSF/ANSI 58 for the specific performance 
claims as verified and substantiated by the test data. These are the only units certified 
by WQA. 
2
 Product output is measured to atmosphere with feed water of 77 degrees F, 60 PSIG 
and 360 ppm TDS. 
3
WQA production is measured against a pressure tank @ 5 psi backpressure,  
77 degrees F, 50 PSIG and 750 mg/L ± 40 mg/L TDS,  
1 NTU turbidity 7.5 ± 0.5 pH, 1 US/cm.
4
 LC50P and LC100P use dual function prefilter for chlorine taste and odor removal.  
Note: Actual production rates may vary depending on water temperature, pressure, TDS 
level and membrane type. 
5
 Efficiency Rating means the percentage of the influent water to the system that is 
available to the user as reverse osmosis treated water under operating conditions that 
approximate typical daily usage. 
6
Recovery Rating means the percentage of the influent water to the membrane portion of 
the system that is available to the user as reverse osmosis treated water when the 
system is operating without a storage tank or when the storage tank is bypassed.
WaterMax RO Owner’s Manual 
11/11/2009
43