Yamaha RX-V1900BL User Manual

Page of 146
34
 En
Optimizing the speaker setting for your listening room
4
Press 8
ENTER to start the measurement.
Loud test tones are output from each speaker during 
the measurement. Once all items for the first listening 
position are measured, the following message 
appears.
• During the automatic setup procedure, do not perform any 
operation on this unit.
• The measurement is canceled if an error occurs (page 32).
5
Move the optimizer microphone to the 
second listening position and then press 
8
ENTER to start the measurement.
y
To skip the measurements at the remaining listening 
positions, press 8n.
6
Repeat step 5 until the measurement at all 
listening positions are made.
If you have made the measurement at all listening 
positions or skipped the measurement at the 
remaining listening positions, the following message 
appears.
7
Follow steps 4 to 10 in “Basic automatic 
setup” (page 30) to c
heck the setup result 
and exit from “SET MENU”.
In case you are not satisfied with the speaker setup and 
sound adjustments made in “MANUAL SETUP”, you can 
restore the settings back to the values configured by the 
last automatic setup.
If you reload the automatic setup parameters, the settings you 
have made in “MANUAL SETUP” are cleared. To save the 
settings before reloading the automatic setup parameters, see 
“SYSTEM MEMORY” (page 86).
1
Set the operation mode selector to E
AMP 
and then press H
MENU.
The top “SET MENU” screen appears in the OSD.
2
Press 8k / n repeatedly to select “AUTO 
SETUP” and then press 
8
ENTER.
3
Check if “SETUP” is selected and then press 
8
l / h repeatedly to select “RELOAD”.
4
Press 8k / n repeatedly to select “START” 
and then press 
8
ENTER.
The results of the last automatic setup are displayed.
y
For details about automatic setup results and how to 
display the setup results in detail, see “Basic automatic 
setup” (page 30).
5
Press 8k / n repeatedly to select “SET” and 
then press 
8
ENTER.
The automatic setup parameters are reloaded.
y
To cancel reloading the automatic setup parameters, press 
8
l / h repeatedly to select “CANCEL” and then press 
8ENTER.
Before proceeding next operation
Once you perform the next operation, this unit starts the 
automatic setup procedure in 10 seconds. For more accurate 
measurements, we recommended that you get out of the room 
or move to the wall where speakers are not around during the 
measurement.
Notes
[ENTER]:
[ ]
:
p
AUTO SETUP
Put the microphone
at 2nd listening
position
Next
Skip
AUTO SETUP
Measurement Complete
Press [ENTER]
Reloading the automatic setup 
parameters
Note