MULTI Inputs   
A set of RCA inputs accept up to 7.1 chan-
nels of analog signals from a DVD-A or 
SACD player. There are inputs for FRONT L 
& R, CENTER, SUB, REAR L & R, and CEN-
TER BACK 1 & 2. 
These inputs bypass all digital processing in 
the RSP-1069 and are routed directly to the 
Volume control and preamp outputs.
There are two subwoofer options for the MULTI 
input. Normally, the .1 channel input is passed 
through directly to the subwoofer output. An 
optional bass redirect feature duplicates the 
7 main channels, sums them, and sends this 
mono signal through a 100 Hz analog low 
fi lter to the subwoofer output. This provides 
an unaltered analog bypass for the seven 
main channels along with a subwoofer sig-
nal derived from those channels.
Preamp Outputs   
A group of ten RCA analog audio outputs 
sends the RSP-1069’s line level output signals to 
external amplifi ers and powered subwoofers. 
These outputs are variable level, adjusted by 
the RSP-1069 volume control. The eight connec-
tors provide output for: FRONT L & R, CENTER 
1 & 2, SURROUND L & R, CENTER BACK CB1 
& CB2, and SUBWOOFER 1 & 2. 
NOTE
Depending on your system confi gura-
tion, you may use some or all of these con-
nections. For example, if you only have one 
center channel, connect it to the CENTER 1 
output. If you only have one center back chan-
nel, connect it to the CB1 output.
ZONE 2–4 Audio Outputs 
Three pair of RCA jacks, labeled ZONE OUT 
send analog audio signals to audio systems 
in up to three remote zones. These outputs 
can be confi gured as either fi xed or variable 
level using the ZONE SETUP menu.
NOTE
Only analog input signals are available 
at the Zone 2, 3, and 4 outputs. Source com-
ponents connected to only the digital inputs 
are not available in the remote zones.
To confi gure your system for remote zone op-
eration, connect the left and right Zone 2 , 3, 
or 4 outputs on the RSP-1069 to the left and 
right channel inputs of the amplifi er power-
ing the remote zone speakers, using standard 
RCA audio cables. There are also composite 
video outputs for each of the zones.
Other Connections
AC Input 
Your RSP-1069 is confi gured at the factory 
for the proper AC line voltage in the coun-
try where you purchased it (USA: 120 volts/
60Hz AC or CE: 230 volts/50 Hz AC ). The 
AC line confi guration is noted on a decal on 
the back of your unit. 
Plug the supplied cord into the AC INPUT re-
ceptacle on the back of the unit.
NOTE
Memorized settings and video labels 
are preserved indefi nitely, even if the RSP-1069 
is disconnected from AC power.
Master Power Switch 
The large rocker switch on the rear panel is 
a master power switch. When it is in the OFF 
position, power to the unit is completely off. 
When it is in the ON position, the front panel 
STANDBY and remote control ON/OFF but-
tons can be used to activate the unit or put it 
into standby mode. 
NOTE
After all connections are completed, 
the rear panel master power switch should 
be put in the ON position and usually left in 
that position.
12V TRIGGER Connections 
Many Rotel amplifi ers offer the option of turn-
ing them on and off using a 12 volt trigger. 
These six connections provide this 12 volt 
trigger signal from the RSP-1069. When the 
RSP-1069 is activated, a 12 volt DC signal 
is sent from these jacks to the amplifi ers to 
turn them on. When the RSP-1069 is put in 
STANDBY mode, the trigger signal is inter-
rupted and the amplifi ers turn off.
To use the remote turn on feature, connect 
one of the RSP-1069’s 12V TRIG OUT jacks to 
the 12 volt trigger input of a Rotel amplifi er, 
using a cable with mono 3.5 mm mini-plugs 
on both ends. The +12 V DC signal appears 
at the “tip” connector.
NOTE
The 12V Trigger outputs are confi gured 
to turn on in various combinations only when 
specifi c input sources are activated. See the 
INPUT SETUP and ZONE 2–4 SETUP menus in 
the Setup section of this manual for details.
REM IN Jacks   
Four 3.5 mm mini-jacks (labeled EXT, ZONE 
2, ZONE 3, and ZONE 4) receive command 
codes from a third-party infrared receiver or 
Rotel remote zone keypad, These remote IR 
inputs are used when the IR signals from a 
hand held remote control cannot reach the 
front panel IR sensor.
EXT: The EXT jack is used with an outboard 
IR receiver to duplicate the front panel IR 
sensor. This feature is useful when the unit 
is installed in a cabinet and the front panel 
sensor is blocked or when IR signals need to 
be relayed to other components. 
ZONE: The ZONE 2, 3, or 4 jacks are used 
with IR repeater systems to receive signals 
from IR control systems in remote locations. 
For example, remote control signals sent to 
the ZONE 2 jack control the ZONE 2 fea-
tures of the RSP-1069 and can be relayed to 
other components. 
Consult your authorized Rotel dealer for 
information on external receivers and the 
proper wiring of a 3.5 mm mini-plugs to fi t 
the REM IN jacks.
NOTE
The IR signals from the EXT IN and 
ZONE IN jacks can be relayed to source 
components using external IR emitters or 
hard-wired connections from the IR OUT 
jacks. See the following section for additional 
information.
IR OUT Jacks 
The IR OUT 1 & 2 jacks send IR signals received 
at the REM IN ZONE 2–4 jacks or the REM 
IN EXT jack to an infrared blaster or emitter 
placed in front of a source component’s IR 
sensor. In addition, the IR OUT can be hard-
wired to Rotel CD players, DVD players, or 
tuners with a compatible connector. 
These outputs are used to allow IR signals 
from the three remote zones to be sent to the 
source components, or to pass along IR sig-
nals from a remote in the main room when 
the sensors on the source components are 
blocked by installation in a cabinet. 
See your authorized Rotel dealer for informa-