The Advanced MCACC menu
Standing Wave
Use this to display the standing wave related 
adjustment values for the various MCACC 
memories. See Standing Wave on page 62 for 
more on this.
1  Select ‘Standing Wave’ from the 
MCACC Data Check menu.
2  When ‘Filter Channel’ is highlighted, 
use 
i/j to select the channel for which 
you want to check standing wave control.
The standing wave related calibration value 
for the selected channel stored at the selected 
MCACC preset and its graph are displayed.
3  Press 
k to highlight ‘MCACC’, then 
use 
i/j to select the MCACC preset you 
want to check.
Acoustic Cal EQ
Use this to display the calibration values for the 
frequency response of the various channels set 
in the different MCACC presets. See Acoustic 
Calibration EQ Adjust
 on page 63 for more on 
this.
1  Select ‘Acoustic Cal EQ’ from the 
MCACC Data Check menu.
2  When ‘Ch’ is highlighted, use 
i/j to 
select the channel.
The calibration value for the frequency response 
of the selected channel stored at the selected 
MCACC preset and its graph are displayed.
3  Press 
k to highlight ‘MCACC’, then 
use 
i/j to select the MCACC preset you 
want to check.
Data Management
This system allows you to store up to six 
MCACC presets, allowing you to calibrate your 
system for different listening positions (or 
frequency adjustments for the same listening 
position). This is useful for alternate settings 
to match the kind of source you’re listening to 
and where you’re sitting (for example, watching 
movies from a sofa, or playing a video game 
close to the TV).
From this menu you can copy from one preset 
to another, name presets for easier identifica-
tion and clear any ones you don’t need.
!  This can be done in Automatically conducting 
optimum sound tuning (Full Auto MCACC) on 
page 25 or Automatic MCACC (Expert) on page 
60 , either of which you should have already 
completed.
1  Press 
 on the remote control, 
then press HOME MENU.
A Graphical User Interface (GUI) screen 
appears on your TV. Use 
i/j/k/l and 
ENTER to navigate through the screens and 
select menu items. Press RETURN to exit the 
current menu.
2  Select ‘Data Management’ from the 
Home Menu.
3  Select the setting you want to adjust.
!  Memory Rename – Name your MCACC 
presets for easy identification (see Renaming 
MCACC presets
 on page 65 ).
!  MCACC Memory Copy – Copy settings from 
one MCACC preset to another (see Copying 
MCACC preset data
 on page 65 ).
!  MCACC Memory Clear – Clear any MCACC 
presets that you don’t want (see Clearing 
MCACC presets
 on page 65 ).
Renaming MCACC presets
If you have several different MCACC presets 
that you’re using, you may want to rename 
them for easier identification.
1  Select ‘Memory Rename’ from the 
Data Management setup menu.
2  Select the MCACC preset you want to 
rename, then select an appropriate preset 
name.
Use 
i/j to select the preset, then k/l to 
select a preset name.
3  Repeat for as many MCACC presets 
as necessary, then press RETURN when 
you’re finished.
You will return to the Data Management setup 
menu.
Copying MCACC preset data
If you want to manually adjust the Acoustic 
Calibration EQ (see Manual MCACC setup on 
page 62 ), we recommend copying your current 
settings to an unused MCACC preset. Instead 
of just a flat EQ curve, this will give you a refer-
ence point from which to start.
!  The settings made in Automatically conducting 
optimum sound tuning (Full Auto MCACC) on 
page 25 or Automatic MCACC (Expert) on page 
60 .
1  Select ‘MCACC Memory Copy’ from the 
Data Management setup menu.
2  Select the setting you want to copy.
!  All Data – Copies all the settings of the 
selected MCACC preset memory.
!  Level & Distance – Copies only the channel 
level and speaker distance settings of the 
selected MCACC preset memory.
3  Select the MCACC preset you’ll be 
copying the settings ‘From’, then specify 
where you want to copy them (‘To’).
Make sure you don’t overwrite an MCACC 
preset you’re currently using (this can’t be 
undone).
4  Select ‘OK’ to confirm and copy the 
settings.
When MCACC Memory Copy? is displayed, 
select YES. If NO is selected, the memory is not 
copied.
Completed! shows in the GUI screen to 
confirm the MCACC preset has been cop-
ied, then you automatically return to the 
Data Management setup menu.
Clearing MCACC presets
If you are no longer using one of the MCACC 
presets stored in memory, you can choose to 
clear the calibration settings of that preset.
1  Select ‘MCACC Memory Clear’ from the 
Data Management setup menu.
2  Select the MCACC preset you want to 
clear.
Make sure you don’t clear an MCACC preset 
you’re currently using (this can’t be undone).
3  Select ‘OK’ to confirm and clear the 
preset.
When MCACC Memory Clear? is displayed, 
select YES. If NO is selected, the memory is not 
cleared.
Completed! shows in the GUI screen 
to confirm the MCACC preset has been 
cleared, then you automatically return to the 
Data Management setup menu.