Sony STR-DE895 Manual

Page of 76
Operations Using the Remote RM-PP412 and RM-PG412
STR-DE995/895
4-244-963-11(1)GB
55
GB
To activate the input source after
programming
Press the programmed button to activate the
input source you want.
To cancel learning
Press USE MODE during any step. The remote
automatically exits the learning mode.
To clear the learned codes
Start over from step 1. After step 3, press
TV ?/1 for more than 2 seconds. The indicator
lights twice slowly and the learned code is
cleared. If TV ?/1 is pressed less than 2
seconds, the learning procedure returns to the
beginning of step 5.
When a learned code is cleared, if the button
was previously programmed for another input
selector, the programmed code for that button
can be used.
To clear the memory of the remote
To clear all programmed and learned signals,
do the following to reset the remote to factory
settings.
Press  ?/1, AV  ?/1, and MASTER VOL –
at the same time.
The indicator flashes 3 times, then goes off.
To use a command that has been
learned
When selecting a learned input selector, press
the learned button for that input selector.
Performing several
commands in sequence
automatically
(Macro Play)
(RM-PG412 only)
The Macro Play function lets you link several
IR codes in a sequential order as a single
command. The remote provides 2 macro lists
(M1 and M2). You can specify up to 10 IR
codes for each macro list.
Setting the sequence of IR codes
1
Press M1 (or M2) while pressing down
USE MODE.
The indicator lights.
2
Press the numeric buttons to select the
macro step number.
For example, to program step 1, press 1.
The indicator blinks slowly.
3
Point the remote control code receiver
section of the remote towards the
receiver/transmitter on the remote
control to be learned.
4
Press the appropriate button on the
remote control to be learned to send
the remote button code.
Lightly pressing the button once should be
sufficient.
If learning is completed successfully, the
indicator slowly flashes twice and the
remote automatically exits the learning
mode.
When learning is not completed
successfully, the indicator flashes 4 times in
quick succession and the procedure returns
to step 4.
5
Repeat steps 1 through 4 to program up
to 10 IR codes.
continued