e.  ADC Level - Otional 
 
The ADC Level menu is accessible when the optional analog input module (A/D converter) 
is installed. Here  it is  possible to choose  between the  inputs on the analog  input module 
and  assign  each  input  a  LOW  and  HIGH  level.  When  the  LOW  level  is  selected  no 
amplification of the analog inputs is performed, whereas when the HIGH level is selected 
an amplification of +6 dB is performed. 
 
f.  Communication 
 
The sub menus accessible in the Communication menu are: 
 
•  Comm Speed 
•  Comm Address 
 
 
The  Communication  setting  signals  the  TDA  2200’s  identity  to  the  PC  interface  or  other 
Lyngdorf products. In master mode the amplifier setting is normally 1, and the addresses 
2-99 can be used for individual slave amplifiers, but nothing is restricted. In the menu the 
current  address  and  the  new  address  is  shown,  The  Up/Down  keys  can  be  used  for 
changing  the  new  setting,  and  a  new  selection  is  stored  with  Enter  which  also  exits  the 
menu  again.  Pressing  Menu  again  exits  the  menu  without  changing  the  current  settings. 
The PC software must know the address of the TDA 2200 in order to communicate with it. 
 
 
 
The Comm Speed setting is the RS232 Link interface speed. The default setting is 57600 
baud. With different PC’s and different lengths of cables the settings can be changed for 
faster communication  to 9600 or 115200  baud. If a multi-amplifier  set-up is installed with 
Master/Slave communication, a smaller delay can be observed when using higher speeds.