6. TECHNICAL SPECIFICATIONS
AUDIO INPUT
Type
Impedance
Operating level
Maximum input level
CMRR
AUDIO OUTPUT
Type
Impedance
Maximum output level
SYSTEM SPECIFICATIONS
Bandwidth
THD+N%
IMD
Noise
Frequency response
Low cut
High cut
PARAMETRIC FILTER
Level
Frequency
Bandwidth
FUNCTION SWITCHES
Audio IN/OUT
I/O meter IN/OUT
IN/OUT
INDICATORS
Input/output level
Function switch
POWER SUPPLY
Main voltages
Power consumption
Fuse
PHYSICAL
Dimension
Weight
Active balanced XLR and 1/4" JACK
Balanced: 50kOhm Unbalanced: 25kOhm
+4dBu/
10dBV
Balanced and Unbalanced: +18dBV
>55dB @1kHz
XLR and 1/4" JACK
Balanced: 60Ohm Unbalanced: 30Ohm
+18dBV
18Hz to 30kHz at
3dBV
0.02% typ. 1kHz, @+4dBu
0.04% typ. 1kHz, @
10dBu
0.01% typ
>-92dBr unweighted 22Hz to 22kHz
18Hz to 28kHz,
3dB
Variable (10Hz to 400Hz)
Variable (
kHz to
kHz)
2.5
30
Variable (
15dB)
Band1: 20Hz to 400Hz
Band2: 60Hz to 1kHz
Band3: 150Hz to 2.5kHz
Band4: 500Hz to 8kHz
Band5: 1kHz to 20kHz
Variable (0.03 to 1.6 octaves)
Relay controlled hard
bypass
Switches the meter display from input to output
Activates each filter band
12-segment LED display:
-30/-24/-18/-12/-6/-3/0/+3/+6/+9/+12/+18dB
LED indicator of every switch
AC: 210
240VAC~50Hz
AC: 95
120VAC~60Hz
9watts
95
120V: T315mA 250VAC
483(W)
194.1(D)
44(H)mm
3.23kg
210
240V: T200mAL 250VAC