Nilfisk Alto CONTROL60 User Manual

Page of 18
Band Pass Filters
High pass Butterworth
Low pass Butterworth
Freq
Freq
20Hz
20KHz step 1/12 oct
Slope
Slope
AUX Section
Delay line
Up to 512 ms min step 21us
Digital input gain
/+12dB step 0.5dB
Digital output volume
/+12dB step 0.5dB
Analog Input Section
Inputs
2 XLR
F electronically balanced
Input Impedance
>40 Kohms
Max. Input Level
2 XLR
M electronically balanced
<200 Ohms
+12dBv
20Hz
20KHz
>99 dB
0.01
1KHz
3 dBFS
Sampling Frequency
Conversion
Input 20 bits Sigma-Delta
Conversion
Output 24 bits Sigma-Delta
Analog Output Section
Outputs
Output Impedance
Max. Output Level
Digital/Analog Interface
Amplitude Response
Signal to Noise Ratio
THD+N
46.875 KHz
+12dBv
Memory
Factory preset
36 (6 for each EQ type)
User preset
63
MIDI Section
Connections
Input/output/thru
Sockets
5
poles DIN(female)
mode
Photocoupled
Power Supply
Connector type
3
pole IEC, grounded
Type
Servo controlled, switching
AC Input
95
240V~60
50Hz
Rated power consumption
15W
fuse
210
240V: T250mAL 250VAC
95
120V: 500mAL 250VAC
User Interface
Graphic Display
128
64 dot
Keyboard
14 user keys/8 LEDs
Vu
meter
2
6 LEDs
Physical
Size
Standard 19"rack mounting
Dimensions
483(W)
232.5(D)
44(H)mm(19"
9.3"
1.7")
weight
3.5Kg(7.72lb)
6.TECHNICAL SPECIFICATIONS
Parametric Filters
Gain
/+15dB step 0.5dB
Freq
20Hz
20KHz step 1/12 oct
Bandwidth
0.05oct
3oct step 0.05oct
Bypass, 1 ord (
6dB/oct), 2 ord (
12dB/oct)
st
nd
20Hz
20KHz Step 1/12 oct
Bypass, 1 ord (
6dB/oct), 2 ord (
12dB/oct
st
nd
15