4 -  47
4. OPERATION
4.6.3 Group designation
When using several servo amplifiers, command-driven parameter settings, etc. can be made on a group
basis.
You can set up to six groups, a to f. Set the group to each station using the communication command.
(1) Group setting example
CHARGE
MITSUBISHI
RS-422
CHARGE
MITSUBISHI
CHARGE
MITSUBISHI
CHARGE
MITSUBISHI
CHARGE
MITSUBISHI
CHARGE
MITSUBISHI
CHARGE
MITSUBISHI
CHARGE
MITSUBISHI
CHARGE
MITSUBISHI
CHARGE
MITSUBISHI
Group d
Group c
To CN3 
Group a
Controller
Axis 1 
(Station 0)
Axis 2 
(Station 1)
Axis 3 
(Station 2)
Axis 4 
(Station 3)
Axis 5 
(Station 4)
Group b
To CN3 
To CN3 
To CN3 
To CN3 
For cable connection diagram, 
refer to Section 8.1.1.
Axis 6 
(Station 5)
To CN3
Axis 7 
(Station 6)
To 
CN3
Axis 8 
(Station 7)
To CN3
Axis 9 
(Station 8)
To 
CN3
Axis 10 
(Station 9)
To CN3
Servo amplifier station No.
Group setting
Station 0
Station 1
Station 2
Station 3
a
Station 4
Station 5
b
Station 6
Station 7
c
Station 8
Station 9
d